Immunoenzyme test system for the quantitative determination of tetanus antitoxin in vaccinated persons using horseradish peroxidase-conjugated staphylococcal protein a

Ponomareva, A.M.; Popkov, M.I.; Bulk, V.F.; Perel'man, E.V.

Zhurnal Mikrobiologii Epidemiologii i Immunobiologii 9: 71-74

1987


ISSN/ISBN: 0372-9311
PMID: 3318246
Document Number: 286780
An enzyme immunoassay (EIA) system for assays of tetanus antitoxin in vaccinees has been developed. As conjugate, staphylococcal protein A labeled with horse-radish peroxidase is used in this system. The possibility of using the newly developed EIA system in seroepidemiological surveys of the population is shown.