Conditions and limits of serum LH radioimmunoassay in normal, hypophysectomized or castred rats
André, M.; Boucher, D.; Thiéblot, L.
Comptes Rendus des Seances de la Societe de Biologie et de ses Filiales 170(2): 353-361
1976
ISSN/ISBN: 0037-9026 PMID: 134803 Document Number: 98754
Serum LH was measured by radioimmunoassay (NIAMD Kits) free and linked hormones were separated by double antibodies method. Influence of concentration on antibody-hormone complex is studied. Hypophysectomised rats serum does not modify results. The standard (rat LH-RP1) has the same action as serum LH. Rat serum LH contents are measured in normal or castred rats.