In vitro study of buffer capacity of blood as a function of hemoglobin concentration in rabbits
Denis, P.; Féret, J.; Pasquis, P.; Lefrançois, R.
Comptes Rendus des Seances de la Societe de Biologie et de ses Filiales 169(2): 296-300
1975
ISSN/ISBN: 0037-9026 PMID: 126759 Document Number: 83692
Rabbit blood samples with different hemoglobin contents were equilibrated with 3,5 and 7% of CO2 in air permetting buffer line determination. Normal buffer line was --24.5 +/- 1.45 Slyke (M +/- 1 SE). The buffer line/hemoglobin concentration calculated regression line was beta = 2.46 [Hb] + 6.56. These data are compared with results obtained in human blood.