Therapeutic effect of flush fitting scleral lenses and hydrogel bandage lenses
Gould, H.L.
International Surgery 58(7): 469-472
1973
ISSN/ISBN: 0020-8868 PMID: 4541534 Document Number: 67463
Document emailed within 1 workday
Related Documents
Ros, F.E.; Tijl, J.W.; Faber, J.A. 1991: Bandage lenses: collagen shield vs. hydrogel lens Clao Journal: Official Publication of the Contact Lens Association of Ophthalmologists Inc 17(3): 187-190Kotynia, K.; Kocela, A.; Filipecki, J.; Filipecka, K.; Korzekwa, P.; Golis, E. 2013: Structural studies of polymer hydrogel and silicone hydrogel contact lenses by means of positron lifetime spectroscopy methods Polimery W Medycynie 43(1): 21-28
Srur, M.; Dattas, D. 1997: The use of disposable contact lenses as therapeutic lenses Clao Journal: Official Publication of the Contact Lens Association of Ophthalmologists Inc 23(1): 40-42
Braff, S.M. 1976: Scleral lenses Journal of the American Optometric Association 47(3): 321
Feldman, G.L. 1975: Photokeratoscopy in the fitting of soft contact lenses Annals of Ophthalmology 7(4): 517
Harris, M.G.; Sarver, M.D.; Polse, K.A. 1977: Patient response to thin hydrogel contact lenses Journal of the American Optometric Association 48(3): 295-299
Hart, D.E.; DePaolis, M.; Ratner, B.D.; Mateo, N.B. 1993: Surface analysis of hydrogel contact lenses by ESCA Clao Journal: Official Publication of the Contact Lens Association of Ophthalmologists Inc 19(3): 169-173
Wasserman, D.; Itzkowitz, J.; Kamenar, T.; Asbell, P.A. 1992: Corneal topographic data: its use in fitting aspheric contact lenses Clao Journal: Official Publication of the Contact Lens Association of Ophthalmologists Inc 18(2): 83-85
Snyder, C.; Hammack, G.G. 1994: Daily disposed hydrogel lenses--a comparison with biweekly replacement Journal of the American Optometric Association 65(3): 164-168
McConville, P.; Pope, J.M. 2001: Diffusion limited evaporation rates in hydrogel contact lenses Clao Journal: Official Publication of the Contact Lens Association of Ophthalmologists Inc 27(4): 186-191
Hart, D.E. 1987: Surface interactions on hydrogel contact lenses: scanning electron microscopy (SEM) Journal of the American Optometric Association 58(12): 962-974
Josephson, J.E. 1978: A corneal irritation uniquely produced by hydrogel lathed lenses and its resolution Journal of the American Optometric Association 49(8): 869-870
Smith, M.F.; Doyle, J.W. 1996: Use of oversized bandage soft contact lenses in the management of early hypotony following filtration surgery Ophthalmic Surgery and Lasers 27(6): 417-421
Wick, B. 1978: Nearpoint symptoms associated with change from spectacle lenses to contact lenses Journal of the American Optometric Association 49(11): 1295-1297
Jain, M.R. 1976: Flexible contact lenses and our experience with 'Sauflon 70' lenses in aphakia Indian Journal of Ophthalmology 23(4): 5-13
Herman, J.P. 1983: Flexure of rigid contact lenses on toric corneas as a function of base curve fitting relationship Journal of the American Optometric Association 54(3): 209-213
de Brabander, J.; Kok, J.H.C.; Nuijts, R.M.M.A.; Wenniger-Prick, L.J.J.M. 2002: A practical approach to and long-term results of fitting silicone contact lenses in aphakic children after congenital cataract Clao Journal: Official Publication of the Contact Lens Association of Ophthalmologists Inc 28(1): 31-35
Brown, B.G. 1981: Management of refractive errors in myopic athletes. A comparison of the Bausch and Lomb Soflens (Polymacon) contact lenses with glasses, hard lenses, and no correction Contact and Intraocular Lens Medical Journal 7(2): 123-143
Hardten, D.R.; Holland, E.J.; Doughman, D.J.; Nelson, J.D. 1992: Early postkeratoplasty astigmatism following placement of anterior chamber lenses and transsclerally sutured posterior chamber lenses Clao Journal: Official Publication of the Contact Lens Association of Ophthalmologists Inc 18(2): 108-111
Dennis, R.J.; Hill, J.R.; Ketchum, N.S. 1991: The durability of hydrogel extended-wear contact lenses worn for daily wear by USAF aircrew members Aviation Space and Environmental Medicine 62(6): 565-568