Effect of head circumference on parameters of pattern reversal visual evoked potential in healthy adults of central India
Kothari, R.; Singh, R.; Singh, S.; Bokariya, P.
Nepal Medical College Journal Nmcj 14(2): 75-79
2012
ISSN/ISBN: 2676-1319 PMID: 23671950 Document Number: 657611
Visual evoked response testing has been one of the most exciting clinical tools to be developed from neurophysiologic research in recent years and has provided us with an objective method of identifying abnormalities of the afferent visual pathways. Investigation were carried out to see whether the head circumference influence the pattern reversal visual evoked potential (PRVEP) parameters. The study comprised of pattern reversal visual evoked potential (PRVEP) recordings in 400 eyes of 200 normal subjects. Two hundred fourty eight eyes were males and 152 eyes were from 76 female subjects recruited from the Central Indian population in the age range of 40-79 years. Visual evoked potential (VEP) recordings were performed in accordance to the standardized methodology of International Federation of Clinical Neurophysiology (IFCN) Committee Recommendations and International Society for Clinical Electrophysiology of Vision (ISCEV) Guidelines and montages were kept as per 10-20 International System of EEG Electrode placements. The stimulus configuration in this study consisted of the transient pattern reversal method in which a black and white checker board was generated (full field) and displayed on a VEP Monitor by an electronic pattern regenerator inbuilt in an Evoked Potential Recorder (RMS EMG EP MARK II). VEP latencies, duration and amplitude were measured in all subjects and the data were analyzed. The correlation of all the electrophysiological parameters with head circumference was evaluated by Pearson's correlation co-efficient (r) and its statistical significance was evaluated. The prediction equations for all the VEP parameters with respect to head circumference were derived. We found a positive correlation of P 100 latency and N 155 latency with mean head circumference, while a highly significant negative correlation were noted of P 100 amplitude with head circumference. N 70 latency was significantly correlated with head circumference. P 100 duration showed in negative correlation with head circumference. These findings suggest that VEP latencies, duration and amplitude are influenced by the head circumference of the individual in a sample of healthy subjects and head circumference can be a useful predictor of VEP peak latencies, amplitude and duration.