Study on testing methods of the elastic nature for equivalent material of human skin
Xie, C.; Liu, N.; Lin, D.; Guo, Z.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 24(1): 219-221
2007
ISSN/ISBN: 1001-5515 PMID: 17333926 Document Number: 606055
To the specificity of equivalent material of human skin mechanical properties, the static-load pressing method for testing the elastic nature of the equivalent material of human skin is proposed, and the designs experimental set for the test is designed. The result show that the method is correct and feasible.
Document emailed within 1 workday
Related Documents
Wattanakrai, P.; Suwanachote, S.; Kulkollakarn, S.; Rajatanavin, N. 2007: The study of human skin irritation of a novel herbal skin care product and ingredients by human single closed patch testing Journal of the Medical Association of Thailand 90(6): 1116-1122Briscoe, D.M.; Dharnidharka, V.R.; Isaacs, C.; Downing, G.; Prosky, S.; Shaw, P.; Parenteau, N.L.; Hardin-Young, J. 1999: The allogeneic response to cultured human skin equivalent in the hu-PBL-SCID mouse model of skin rejection Transplantation 67(12): 1590-1599
Ferri, S. 1980: Elastic system fibers (oxytalan, elaunin and elastic fibers) in the skin of a freshwater teleost : optical and electron microscopy study Archives d'Anatomie Microscopique et de Morphologie Experimentale 69(4): 259-266
Streit, M.; Braathen, L.R. 2000: Apligraf--a living human skin equivalent for the treatment of chronic wounds International Journal of Artificial Organs 23(12): 831-833
Kostowiecki, M. 1971: Relationship of the elastic fibers to Meissner's corpuscles in the aging human skin Zeitschrift für Mikroskopisch-Anatomische Forschung 84(2): 199-218
Ramelet, A.A.; Debure, C.; Lok, C.; Meaume, S.; Guilhou, J.J.; Senet, P. 1999: Rapid healing of venous ulcers and lack of clinical rejection with an allogeneic cultured human skin equivalent Annales de Dermatologie et de Venereologie 126(4): 380-384
Brooks, C.D.; Karl, K.J.; Francom, S.F. 1994: ATGAM skin test standardization. Comparison of skin testing techniques in horse-sensitive and unselected human volunteers Transplantation 58(10): 1135-1137
Cvitanović, S.; Grbić, D.; Zekan, L.; Boban, M.; Vrdoljak, E.; Parpura, V.; Petrović, S.; Marusić, M. 1989: Hypersensitivity to P. officinalis pollen: correlation of IgE with skin testing methods Allergologia et Immunopathologia 17(4): 197-200
Wallengren, J.; Ekman, R.; Sundler, F. 1987: Occurrence and distribution of neuropeptides in the human skin. An immunocytochemical and immunochemical study on normal skin and blister fluid from inflamed skin Acta Dermato-Venereologica 67(3): 185-192
Bartlett, D.T.; Greenhalgh, J.R. 1986: Calculations of effective dose equivalent, ambient dose equivalent and individual dose equivalent for a set of reference neutron spectra and field geometries Health Physics 50(4): 548-550
Osanov, D.P.; Radzievsky, G.B.; Tissen, M.J. 1972: On the applicability of the method based on the transport theory to the determination of dose distribution of -radiation in a tissue-equivalent material Health Physics 23(6): 872-874
Welker, D. 1971: Results of material testing of polyacrylate cements. l. Tests on powders and liquids; study of properties during manufacture Deutsche Stomatologie 21(6): 433-439
Furlan, C.; De Bac, C. 1978: Histochemical study of HBsAg on paraffin sections of biopsy material using various staining methods: comparative evaluation Bollettino della Societa Italiana di Biologia Sperimentale 54(3): 258-263
Roumiantzeff, M.; Colombet, G. 1977: C. parvum skin testing antigen: study on guinea pig model Developments in Biological Standardization 38: 65-72
Semkin, V.I.; Mikhaĭlov, I.N. 1990: Studies of human skin by cryofractographic and electron-microscopic methods Arkhiv Anatomii Gistologii i Embriologii 99(7): 63-67
Dunnebacke, T.H.; Schuster, F.L. 1977: The nature of a cytopathogenic material present in amebae of the genus Naegleria American Journal of Tropical Medicine and Hygiene 26(3): 412-421
Li, H.; Yun, H.-Y.; Baek, K.J.; Kwon, N.S.; Park, K.-C.; Kim, D.-S. 2014: Myriocin, a serine palmitoyltransferase inhibitor, increases melanin synthesis in Mel-Ab cells and a skin equivalent model Die Pharmazie 69(3): 187-191
Solano Reina, E. 1992: Elastic activator appliances: Bimler's elastic appliance and Klammt's elastic activator L' Orthodontie Francaise 63 Pt 2: 373-380
Zernahle, K. 1979: Human cytogenetic study methods--value and use. II. Banding methods in chromosome diagnosis Zeitschrift für Arztliche Fortbildung 73(15): 701-708
Kaewruttanapattama, F.; Chokboonpium, J.; Thammahong, A.; Klaewsongkram, J. 2010: A comparison between morphine and histamine as a positive control agent for intradermal skin testing: an evidence-based study Journal of Investigational Allergology and Clinical Immunology 20(7): 626-627