Using optical coherence tomography to guide articular cartilage ablation

Patel, N.A.; Li, X.; Stamper, D.L.; Fujimoto, J.G.; Brezinski, M.E.

American Journal of Orthopedics 34(3): 111-115

2005


ISSN/ISBN: 1078-4519
PMID: 15828512
Document Number: 589392
Current clinical imaging technologies are not capable of accurately resolving the microscopic components of articular cartilage. Optical coherence tomography (OCT) is a recently developed imaging modality analogous to ultrasound--OCT measures backreflection of infrared light instead of sound. In the study reported here, we wanted to determine the efficacy of OCT for monitoring cartilage laser ablation. Real-time imaging was conducted on bovine cartilage ablated by an argon laser in vitro. Image sequences were generated illustrating the extent of tissue degradation postablation. The images accurately correlated with histology. These results indicate that current ablation procedures could benefit from OCT guidance.