First experience of use of a double balloon three-lumen catheter for decreasing the time of heat ischemia in asystolic kidney donors in Russia
Bagnenko, S.F.; Moĭsiuk, I.G.; Reznik, O.N.
Vestnik Khirurgii Imeni I. I. Grekova 163(2): 99-103
2004
ISSN/ISBN: 0042-4625 PMID: 15199783 Document Number: 570368
The authors consider actual problems of transplantation of organs associated with using donors. Special attention is given to current methods of preservation and obtaining donor kidneys from irreversible cardiac arrest donors. The authors propose to use a standard protocol of measures aimed at obtaining high quality transplants in every day practice of surgical teams dealing with taking off donor organs. First positive results of using the proposed method are described.
Document emailed within 1 workday
Related Documents
Murugesan, N.; Gowdle, C.P.; Durgaprasad, P.; Ramalingam, K.S.; Mani, M.K. 1987: Hemodialysis using single lumen subclavian catheter and double blood pump--an initial experience Journal of the Association of Physicians of India 35(9): 619-621Koffman, C.G.; Bewick, M.; Chang, R.W.; Compton, F. 1993: Comparative study of the use of systolic and asystolic kidney donors between 1988 and 1991. the South Thames Transplant Group Transplantation Proceedings 25(1 Part 2): 1527-1529
Cavicchioni, C.; Marino, I.R.; De Luca, G.; Ceriati, F. 1988: Emergency vascular access with a double-lumen subclavian catheter Minerva Chirurgica 43(17): 1371-1376
Geary, D.F.; McLorie, G.A.; Bahoric, A.; Sakai, H.; Albisser, A.M.; Balfe, J.W. 1989: Continuous flow peritoneal dialysis in pigs, using a silicone rubber double lumen catheter International Journal of Artificial Organs 12(7): 428-432
Martens, M.G.; Faro, S.; Hammill, H.; Phillips, L.E.; Riddle, G.D. 1989: Comparison of two endometrial sampling devices. Cotton-tipped swab and double-lumen catheter with a brush Journal of Reproductive Medicine 34(11): 875-879
Benoit, G.; Bensadoun, H.; Borie, I.; Vavasseur, G.; Gillot, C. 1990: A double balloon catheter for the procurement of abdominal organs Annales d'Urologie 24(3): 199-201
Fontes, V.F.; Esteves, C.A.; Silva, M.V.; Pimentel Filho, W.A.; Souza, J.E. 1987: Double valvuloplasty with aortic and pulmonary balloon catheter. A case report Arquivos Brasileiros de Cardiologia 48(2): 105-107
Gomes, N.L.; Esteves, C.A.; Braga, S.L.; Ramos, A.; Meneghelo, Z.M.; Mattos, L.A.; Sousa, A.G.; de Almeida, C.T.; Fontes, V.F.; Sousa, J.E. 1993: Mitral double catheter-balloon valvuloplasty, hemodynamics evaluation of 52 cases one year after the procedure Arquivos Brasileiros de Cardiologia 60(5): 307-310
Nouri, M.; Tligui, M.; Flahaut, A.; Tchala, K.; Doublet, J.D.; Haab, F.; Traxer, O.; Thibault, P.; Gattegno, B. 2000: Balloon catheter parieto-renal dilatation in percutaneous kidney surgery Progres en Urologie: Journal de l'Association Francaise d'Urologie et de la Societe Francaise d'Urologie 10(6): 1131-1134
Sumethkul, V.; Jirasiritham, S.; Chiewsilp, P.; Domrongkitchaiporn, S.; Sujirachato, K.; Mongkolsuk, T.; Sriphojanart, S.; Kanjanapanjapol, S.; Chakkaphak, S.; Leela-Udomlipi, S.; Leenanupunth, C.; Tirapanich, W.; Chaimuangraj, S.; Kochakarn, W.; Tapaneya-Olarn, W.; Tardtong, P.; Leungwattanakij, S.; Angkoolpakdeekul, T.; Lertchalorarn, K.; Tansupasiri, P.; Gojaseni, P. 2000: The organization of Kidney Transplantation Services at Ramathibodi Hospital: fourteen years experience on waiting list, kidney donors and kidney transplantation Journal of the Medical Association of Thailand 83 Suppl. 1: S35-S41
Cheng, T.O. 1991: Percutaneous balloon mitral valvuloplasty: Inoue balloon vs double balloon technic Acta Cardiologica 46(4): 493-494
Sørland, S.J.; Bjørnstad, P.G.; Smevik, B.; Stake, G.; Vatne, K. 1987: Balloon dilatation of heart valve stenoses. Treatment of congenital aortic and pulmonary valve stenosis with a balloon catheter (balloon valvuloplasty) Tidsskrift for den Norske Laegeforening: Tidsskrift for Praktisk Medicin Ny Raekke 107(10-11): 947-949
Nadasy, G.L.; Pusztai, P.; Kerényi, T.; Merkel, V.; Tolgyessy, L.; Jellinek, H.; Kovách, A.G.; Monos, E. 1991: Passive geometric and elastic properties of human cadaver common carotid artery segments after intraluminal enzyme digestion with the aid of a four-way double balloon catheter Cor et Vasa 33(1): 58-67
Simmons, R.L.; Tallent, M.B.; Kjellstrand, C.M.; Najarian, J.S. 1971: Kidney transplantation from living donors with bilateral double renal arteries Surgery 69(2): 201-207
Miñana López, B.; Fernández Aparicio, T.; Díaz González, R.; Polo Villar, G.; Aguirre Benites, F.; Fraile Gómez, B.; Morales Cerdán, J.M.; Leiva Galvis, O. 2000: Experience with kidney transplantation with children as donors Archivos Espanoles de Urologia 53(5): 431-442
Vanholder, R.; De Paepe, M.; Hoenich, N.A.; Ringoir, S. 1981: Double lumen needle in unipuncture dialysis type double headpump International Journal of Artificial Organs 4(2): 72-74
Rugiu, C.; Lupo, A.; Bernich, P.; Oldrizzi, L.; Fabris, A.; Fiordaligi, G.; Fattovich, G.; Maschio, G. 1997: 14-year experience with the double-cuff straight Tenckhoff catheter Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 17(3): 301-303
Perner, F.; Hidvégi, M.; Járay, J.; Alföldy, F.; Gyódi, E.; Petrányi, G. 1996: Kidney transplantation from living donors in Hungary: experience of 22 years Transplantation Proceedings 28(6): 3584-3590
Zhou, Y.; Li, G.-h.; Yan, J.-j.; Shen, C.; Tang, G.-h.; Xu, G. 2016: Combination of the ureteral dilation catheter and balloon catheter under the ureteroscope in the treatment of male urethral stricture Zhonghua Nan Ke Xue 22(1): 42-45
Spear, S.L.; Matsuba, H.; Romm, S.; Little, J.W. 1991: Methyl prednisolone in double-lumen gel-saline submuscular mammary prostheses: a double-blind, prospective, controlled clinical trial Plastic and Reconstructive Surgery 87(3): 483-487; Discussion: 488-489