Application of electroosmotic pump on micro column liquid chromatography
Chen, L.-X.; Guan, Y.-F.
Se Pu 20(2): 115-117
2002
ISSN/ISBN: 1000-8713 PMID: 12541964 Document Number: 544444
An electroosmotic pump(EOP) was designed and evaluated, which could replace the mechanical pump. The EOP could generate 2.0 MPa-6.0 MPa output pressure and tens of nL/min-3 microL/min flow rate. A test mixture containing naphthalene, anthracene and phenanthrene was separated on a 14 cm x 320 microns i.d., 5 microns, C18 micro column with acetonitrile/water as a mobile phase, which demonstrated the applicability of the EOP.
Document emailed within 1 workday
Related Documents
Lu, C-Yu.; Wang, Y-Rou.; Chen, S-Hwei.; Feng, C-Hsien. 2010: Analysis of quinapril by two solvent-saving methods: application of capillary column high-performance liquid chromatography with ultraviolet absorbance detection and LDI-TOF-MS Journal - Association of Official Analytical Chemists 93(4): 1201-1206Stroka, J.; von Holst, C.; Anklam, E.; Reutter, M. 2003: Immunoaffinity column cleanup with liquid chromatography using post-column bromination for determination of aflatoxin B1 in cattle feed: collaborative study Journal - Association of Official Analytical Chemists 86(6): 1179-1186
Ishimura, K.; Fukunaga, K.; Irie, T.; Uekama, K.; Ohta, T.; Nakamura, H. 1997: Application of a beta-cyclodextrin sulfate-immobilized precolumn to selective on-line enrichment and separation of heparin-binding proteins by column-switching high-performance liquid chromatography Journal of Chromatography A 769(2): 209-214
Baru, M.B.; Cherskiĭ, V.V.; Danilov, A.V.; Moshnikov, S.A.; Mustaeva, L.G. 1995: The automated "SynChrom" system for solid-phase synthesis of peptides and liquid column chromatography. II. use in the solid-phase synthesis of peptides and liquid column chromatography Bioorganicheskaia Khimiia 21(7): 506-516
De Almeida-Muradian, L.B.; Rios, M.D.; Sasaki, R. 1998: Determination of provitamin a of green leafy vegetables by high performance liquid chromatography and open column chromatography Bollettino Chimico Farmaceutico 137(7): 290-294
Maruyama, S.; Kenmotsu, M.; Igarashi, H.; Hiyoshi, S.; Ishido, T. 1982: Measurement of hemoglobin A1, A1c by micro-column chromatography Rinsho Byori. Japanese Journal of Clinical Pathology 30(3): 320-324
Volin, P. 1992: Determination of urinary normetanephrine, metanephrine and 3-methoxytyramine by high-performance liquid chromatography with electrochemical detection: comparison between automated column-switching and manual dual-column sample purification methods Journal of Chromatography 578(2): 165-174
Zhang, A.L.; Zhou, J.T.; Han, M.; Teng, L.M.; Huang, L.P.; Wang, D.; Wang, J. 2001: Study on analysis of trace phenol in small amount of aqueous sample by liquid-liquid micro-extraction and gas chromatography Se Pu 19(2): 144-146
Duchateau, A.M.; Svendsen, A.B. 1972: The influence of the column tubing material on the gas-liquid chromatography of barbiturtes and some other pharmaceuticals Pharmaceutisch Weekblad 107(25): 377-380
Björkman, S.; Aziz, N.; Stein, D.; Stanski, D.R. 1989: Determination of alfentanil in serum by radioimmunoassay or capillary column gas-liquid chromatography. a comparison of the assays Acta Pharmaceutica Nordica 1(4): 211-220
Walters, M.J. 1984: Determination of histamine in fish by liquid chromatography with post-column reaction and fluorometric detection Journal - Association of Official Analytical Chemists 67(6): 1040-1043
Zou, G.W.; Shi, R.R.; Gao, H. 1985: Separation of catecholamines by micro high-performance liquid chromatography with electrochemical detection Yao Xue Xue Bao 20(11): 870-873
Liu, Z.; Yang, W.; Jin, Y.; Bai, G. 2004: Determination of L-cysteine in enzymatic reaction mixture with pre-column derivatization by high performance liquid chromatography Se Pu 22(3): 231-233
Huang, Y.; Wang, Y.; Miao, M.; Zhao, Q.; Yang, G. 2007: Determination of major carbonyls in mainstream smoke by rapid column high performance liquid chromatography Se Pu 25(2): 230-233
Xie, H.; Zhang, S. 1997: Determination of taurine in Lycium barbarum L. by high performance liquid chromatography with OPA-urea pre-column derivatization Se Pu 15(1): 54-56
Wu, D.F.; Yu, Y.W.; Zheng, D.K. 1988: Determination of (+)- and (-)-gossypol in human plasma using high performance liquid chromatography with pre-column chemical derivatization Yao Xue Xue Bao 23(12): 927-932
Panchal, H.J.; Suhagia, B.N.; Patel, M.M.; Patel, B.H. 2009: Estimation of pitavastatin calcium in tablet dosage forms by column liquid chromatography and ultraviolet spectrophotometry Journal - Association of Official Analytical Chemists 92(1): 158-164
Tang, X.D.; Zhao, J.; Yang, T.Z. 2001: Research on a new side-chain liquid crystalline polysiloxane as stationary phase for capillary column gas chromatography Se Pu 19(3): 264-267
Niemann, R.A. 1993: Determination of formetanate hydrochloride in selected fruits by coupled-column cation exchange liquid chromatography Journal - Association of Official Analytical Chemists 76(6): 1362-1368
Huang, X.H.; Chen, B.M.; Liang, S.X.; Deng, F.L. 2000: High-performance liquid chromatography determination of histamine in nasal mucosa of guinea pig after post-column derivatization Hunan Yi Ke da Xue Xue Bao 25(3): 294-296