Gold implant treatment for discomfort induced by a filtering bleb

Crichton, A.C.; Ashenhurst, M.; Kirker, A.W.

Ophthalmic Surgery and Lasers 32(5): 425-427

2001


ISSN/ISBN: 1082-3069
PMID: 11563788
Document Number: 538664
We present a post-trabeculectomy patient suffering from blurred vision and foreign body sensation that was not alleviated by conventional treatments. Our treatment involved placing a gold weight implant onto the anterior surface of the tarsal plate to gravity-assist closure and increase coverage of the filtering bleb.