An evaluation of Visidex test strips in the blood sugar control of diabetics
Khristov, V.; Manov, A.; Nestorov, I.
Vutreshni Bolesti 30(2): 58-61
1991
ISSN/ISBN: 0506-2772 PMID: 1891901 Document Number: 380030
The test stripes Visidex for visual evaluation of glycemia were tested clinically. The results were compared with a reference laboratory method for blood sugar measurement. A correlation coefficient of r = 0.971 with 74% coincidence in the same glycemic interval was found. The test stripes are suitable for blood sugar self-control in domestic conditions.