Animal experimental studies of periodontal implants of compact macroporous and phycogenic HA-ceramic granules
Bieniek, K.W.; Spiekermann, H.
Zwr 98(11): 958-960
1989
ISSN/ISBN: 0044-166X PMID: 2639542 Document Number: 335434
Four different macro- and microporous, compact bone implant materials were used in minipigs for the periodontal treatment of infrabony defects. The results showed, that the compact materials had minimal osteogenic potential, where as the macroporous materials, especially the phycogenic HA-granules with connecting microporosities showed an intensive osteointegration and appositional reaction.
Document emailed within 1 workday
Related Documents
Bocher, R.; Langanke, B.; Schmidt, W.; von Lengerken, G. 1985: Experimental animal studies of the positional effect of chemically denatured compact bone chips Stomatologie der DDR 35(10): 571-580Zetterqvist, L.; Anneroth, G.; Nordenram, A. 1991: Tissue integration of Al2O3-ceramic dental implants: an experimental study in monkeys International Journal of Oral and Maxillofacial Implants 6(3): 285-293
Krempien, B.; Schulte, W.; Kleineikenscheidt, H.; Lindner, K.; Schareyka, R.; Heimke, G. 1978: Light and scanning electronmicroscopic studies of border surfaces of aluminum oxide-ceramic implants in the dog mandible Deutsche Zahnarztliche Zeitschrift 33(5): 332-340
Krekeler, G.; Düker, J.; Fabinger, A. 1979: Healing of a spongiosa graft in the periodontal pocket (animal experimental study) Deutsche Zahnarztliche Zeitschrift 34(4): 313-316
Di Silvestre, M.; Guizzardi, S.; Bettini, N.; Gargiulo, G.; Savini, R. 1991: Powdered alumina implants in the experimental animal: a histological study conducted in the rat La Chirurgia Degli Organi di Movimento 76(2): 167-172
Takashima, Y. 1971: Cytochemical studies on the components of yolk granules and cortical granules in sea urchin eggs Medical Journal of Osaka University 22(3): 109-127
Krummel, F.J.; Reck, R.; Meyer, A. 1987: Compatibility of glass-carbon implants in the middle ear--animal experiment studies Laryngologie Rhinologie Otologie 66(8): 409-411
Miyachi, Y.; Ueda, S.; Hayakawa, F.; Nakashima, T.; Hakamada, S.; Kuno, K. 1985: Experimental and clinical studies on BRL 25000 (clavulanic acid-amoxicillin) granules in the pediatric field Japanese Journal of Antibiotics 38(2): 423-430
Nakazawa, S.; Sato, H.; Narita, A.; Matsumoto, K.; Nakazawa, S.; Suzuki, H.; Chikaoka, H.; Tazoe, K.; Nakada, Y.; Niino, K. 1985: Experimental and clinical studies on BRL 25000 (clavulanic acid-amoxicillin) granules in the pediatric field Japanese Journal of Antibiotics 38(2): 296-308
Schäfer, A. 1990: Experimental investigation of ceramic materials for bonded metal ceramic systems Zwr 99(7): 558-560
Ning, H.; Liu, H. 2011: Periodontal ligament regeneration using apical tooth germ cell-conditioned medium induced periodontal ligament cells sheet between dental tube and ceramic biologic bone Hua Xi Kou Qiang Yi Xue Za Zhi 29(4): 429-433
Eitenmüller, J.; Gerlach, K.L.; Schmickal, T.; Muhr, G. 1987: Semirigid plate osteosyntheses using absorbable polymers as temporary implants. II. Animal experiment studies Der Chirurg; Zeitschrift für Alle Gebiete der Operativen Medizen 58(12): 831-839
Feinman, R.A. 1994: Periodontal splinting alternatives or periodontal splinting with flexible ceramic bonding Dentistry Today 13(10): 94-95
Sivash, K.M.; Berman, A.M.; Sherepo, K.M.; Morozov, B.P.; Shapiro, I.L. 1979: Response of the compact bone to the mechanical action of metal implants Ortopediia Travmatologiia i Protezirovanie 3: 54-56
Shapira, Y.; Shohami, E. 1993: Experimental studies on brain oedema after blunt head injury: experimental approaches from animal experimentation to actual or possible clinical application European Journal of Anaesthesiology 10(3): 155-173
Alia, E.E.; Sotgiu, F. 1978: Experimental studies on homologous and heterologous cartilage implants Bollettino della Societa Italiana di Biologia Sperimentale 54(19): 1784-1788
Roewer, N.; Schulte am Esch, J. 1994: Prevention of pulmonary aspiration of stomach contents using a new balloon gastric tube. Animal experimental studies, proband studies and initial clinical results Der Anaesthesist 43(1): 16-25
Knöfler, W.; Hampel, H.; Bethmann, W. 1981: Problems in dental implantation. first animal studies on coated titanium blade implants: light optical and scanning electron microscopic evaluation Stomatologie der DDR 31(10): 729-735
Sulejmanagić, H.; Kućanski, B.; Gojkov, T.; Beganović, M. 1983: Clinical studies on aluminum oxide implants in experimental animals Stomatoloski Vjesnik. Stomatological Review 12(3-4): 95-104
Körber, K.H.; Ludwig, K.; Dünner, P. 1984: Experimental studies of the abrasion effect between dental enamel and dental ceramic Deutsche Zahnarztliche Zeitschrift 39(1): 2-11