Serum and plasma compared for use in 19 common chemical tests performed in the Hitachi 737 analyzer
Ciuti, R.; Rinaldi, G.
Clinical Chemistry 35(7): 1562-1563
1989
ISSN/ISBN: 0009-9147 PMID: 2758626 Document Number: 334935
Document emailed within 1 workday
Related Documents
Miura, Y.; Yoshida, H. 1993: Present status and problems of the Hitachi fully automated sample handling system lined with chemical analyzer 7350 e and 7250 Rinsho Byori. Japanese Journal of Clinical Pathology Suppl 95: 67-76Wang, J.; Jiang, H. 1997: Determination of inorganic phosphate in serum by double reagents with Hitachi 7170 A analyzer Hunan Yi Ke Da Xue Xue Bao 22(5): 455-458
Goren, M.P.; Osborne, S.; Simmons, M.J. 1987: CSF total protein determined with the Hitachi 705 analyzer Clinical Chemistry 33(5): 711
Guy, J.M.; Legg, E.F. 1990: Bilirubin interference in determinations of creatinine with the Hitachi 737 analyzer Clinical Chemistry 36(10): 1851-1852
Nakamura, M.; Tadano, J. 1993: On-line system of Toa, Hitachi hematology analyzer in application and practice Rinsho Byori. Japanese Journal of Clinical Pathology Suppl 95: 59-66
Nishikaze, O.; Ichida, A.; Furuya, E. 1971: Changes in the results of clinical chemical tests due to the presence of abnormal components of the serum and its prevention--chemical analysis of the hemolytic, jaundiced and turbid sera Rinsho Byori. Japanese Journal of Clinical Pathology 19: Suppl: 215-6
Emancipator, K. 1991: Urine and serum pregnancy tests compared Clinical Chemistry 37(2): 302-303
Lindberg, C.; Jönsson, S.; Hedner, P.; Gustafsson, A. 1982: Radioimmunoassay and chemical ionization/mass spectrometry compared for plasma cortisol determination Clinical Chemistry 28(1): 174-177
Sturm, B.; Albrecht, R.-Groos and Michael Seyfath 2002: Evaluation of New Oxidation Methods for the Measurement of Bilirubin on the Aeroset Clinical Chemistry Analyzer and Comparison with Methods on the Hitachi 717 Clinical Laboratory 48(7-8): 401-405
Makula, M.F.; Plan, R. 1979: Physico-chemical controls of human placental or plasma albumin-purity tests Developments in Biological Standardization 44: 75-81
Boettcher M.; Haenseler E.; Hoke C.; Nichols J.; Raab D.; Domke I. 2000: Precision and Comparability of Abuscreen OnLine Assays for Drugs of Abuse Screening in Urine on Hitachi 917 with other Immunochemical Tests and with GC/MS Clinical Laboratory 46(1-2): 49-52
Pontet, F.; Laudat, A. 1997: Influence of bilirubin and turbidity on main determinations performed on the Express 550 analyzer Annales de Biologie Clinique 55(5): 472-476
Mizuta, W.; Fukuda, K.; Ashida, H. 1983: Automatic analysis of serum sialic acids by Hitachi 726 Rinsho Byori. Japanese Journal of Clinical Pathology Suppl. 54: 128-134
Pei, P.; Cigler, C.; Vonderschmitt, D.J. 1991: Evaluation of enzymatic methods for the determination of plasma sodium and potassium using the Hitachi 747 analytic system Schweizerische Medizinische Wochenschrift 121(50): 1883-1886
Crickx, B.; Lazareth, I. 1990: Scleroderma. which tests should be performed? Annales de Dermatologie et de Venereologie 117(1): 83-86
Endoh, A.; Yagihashi, A.; Asanuma, K.; Moriai, R.; Izawa, A.; Koyanagi, Y.; Sato, T.; Kobayashi, D.; Watanabe, N. 2001: Hematopoietic progenitor cell counts performed by the Sysmex SE-9000 analyzer can guide timing of peripheral blood stem cell harvest Anticancer Research 21(1b): 601-604
Amog, V.M.; Bull, R.W.; Michel, R.L. 1977: Comparison of electrophoretograms of normal canine serum and plasma and of serum and plasma of hemolyzed specimens American Journal of Veterinary Research 38(3): 387-390
Axelsson, C.G. 1990: Let us avoid cholesterol tests performed by pharmacies! Lakartidningen 87(40): 3172
Yosselson-Superstine, S.; Granit, D.; Superstine, E. 1980: Drug interferences with tests performed by a 12-channel autoanalyzer American Journal of Hospital Pharmacy 37(10): 1333-1338
Borner, K. 1977: The Greiner Selective Analyzer. II. Status of the development of a clinical-chemical autoanalyzer (proceedings) Journal of Clinical Chemistry and Clinical Biochemistry 15(8): 446-447