Puncture of solid tumors of the liver with large caliber needle guided by ultrasonography. Study of 70 punctures

Reix, N.; Joly, J.P.; Sevestre, H.; Capron, J.P.

Gastroenterologie Clinique et Biologique 12(6-7): 508-511

1988


ISSN/ISBN: 0399-8320
PMID: 3046981
Document Number: 326420
Seventy specimens of solid hepatic tumors were obtained for histologic examination with a 18 G (1.2 mm) diameter needle under real-time ultrasound control. Overall sensitivity was 95.6 p. 100 while specificity was 100 p. 100. Distinction between primitive and secondary malignant tumor was possible in 91 p. 100 of cases. Transient hemorrhage at the puncture site occurred in one patient. These results attest to the superiority of guided puncture with a needle of sufficient caliber, thus allowing for correct histologic study. Side effects did not occur more frequently than with fine caliber needles.