Dust in a factory processing chrysotile asbestos: results of simultaneous measurement using several methods

Perunicić, B.; Jablanov, L.

Arhiv Za Higijenu Rada i Toksikologiju 38(4): 323-330

1987


ISSN/ISBN: 0004-1254
PMID: 3453660
Document Number: 304308
Airborne dust levels were measured in a plant manufacturing textile and friction asbestos products in summer and in winter. Measurements were performed with four methods: two granulometric (koniometer (K) and thermal precipitator (TP) and two gravimetric (Stapex and SPG-210) ones. The number of fibres (5 .mu.m), the number of particles down to the limit of detectability and two aerodynamic particle size fractions, respirable and coarse, in the dust mass, were determined. Granulometric measurements showed a statistically significant correlation between fibres and particles for samples of air from asbestos-textile departments. The relations based on linear regression equations could be expressed roughly as: -550 particles/ccm (TP) = 450 particles/ccm (K) -7 fibres/ccm (TP) = 5 fibres/ccm (K) -5 fibres/ccm (TP) = 200 particles/ccm (TP) and -5 fibres/ccm (K) = 280 particles/ccm (K) The results of gravimetric measuremnets of airborne asbestos dust need to be further evaluated.

Document emailed within 1 workday