Analytical and clinical evaluation of Enzymum-test HCG for determining choriogonadotropin in serum
Collette, J.; Adam, A.; Ers, P.; Parmantier, M.; Notche, M.; Demoulin, A.; Franchimont, P.
Clinical Chemistry 33(5): 715
1987
ISSN/ISBN: 0009-9147 PMID: 3568368 Document Number: 295326
Document emailed within 1 workday
Related Documents
Edwards, L.; Doctor, G. 1981: Use of qualitative serum beta-choriogonadotropin test to monitor problem pregnancies Clinical Chemistry 27(2): 339-341Kutuzov, V.A.; Mikhaĭlov, V.V.; Kruglova, S.E.; Kutuzov, V.V.; Kirillov, A.P.; Krasnianskiĭ, V.P.; Pshenichnov, V.A.; Lebedinskaia, E.V. 1993: A comparative evaluation of an immunoenzyme analytical method using a fluorogenic or chromogenic substrate in determining the Marburg virus antigen Voprosy Virusologii 38(1): 17-18
Knight, G.J.; Cole, L.A. 1991: Measurement of choriogonadotropin free beta-subunit: an alternative to choriogonadotropin in screening for fetal Down's syndrome? Clinical Chemistry 37(6): 779-782
Triola, M.; Honorato, J.; Sampol, C.; Martinez Caro, D. 1975: Determination of serum digoxin concentrations using radioimmunoassay. Evaluation and application of the analytical method Revista de Medicina de la Universidad de Navarra 19(1): 1-8
Wians, F.H.; Jacobson, J.M.; Dev, J.; Heald, J.I.; Ortiz, G. 1988: Thyrotroph function assessed by sensitive measurement of thyrotropin with three immunoradiometric assay kits: analytical evaluation and comparison with the thyroliberin stimulation test Clinical Chemistry 34(3): 568-575
Garrett, P.E.; Kurtz, S.R.; Hurd, J.K. 1983: False-positive results for choriogonadotropin in serum Clinical Chemistry 29(10): 1871
Borsuk, E.A.; Vorob'eva, M.S.; Ebralidze, L.K. 1991: The evaluation of a commercial EIA test system for determining the specific activity of antiherpetic preparations Voprosy Virusologii 36(2): 137-140
Heeschen, C.; Goldmann, B.U.; Moeller, R.H.; Hamm, C.W. 1998: Analytical performance and clinical application of a new rapid bedside assay for the detection of serum cardiac troponin i Clinical Chemistry 44(9): 1925-1930
Beinlich, C.J.; Carpenter, R.H. 1987: Automated and manual quantitative assays of choriogonadotropin in serum compared Clinical Chemistry 33(1): 167-169
Delfert, D.M.; Rea, M.R.; Kessler, G.; Siegfried, B.A.; Valdes, R. 1987: Criteria for evaluating nonquantitative assays: application to serum choriogonadotropin Clinical Chemistry 33(1): 150-153
Wallace, J.E.; Harris, S.C.; Shimek, E.L. 1980: Evaluation of an enzyme immunoassay for determining diazepam and nordiazepam in serum and urine Clinical Chemistry 26(13): 1905-1907
Cordovilla, J.J.; de la Fuente, C.; Llorens, V.; Pastor, J.M.; Hermosa, V.; Carril, J.M. 1987: Evaluation of iron deposits in blood donors by determining serum ferritin using radioimmunoassay Revista Clinica Espanola 181(2): 75-78
Schraderolms, B.; Seibel, W.; Pfeilsticker, K. 1986: Analytische, teigrheologische und backtechnische Studien zur Optimierung des Weizen-Backversuches, Rapid-Mix-Test - Etude bromatologique, rhéologique et technologique d'optimisation du «Rapid-Mix-Test» de panification du blé. II. Travaux préliminaires pour l'optimisation des essais de panification par le «Rapid-mix-test» - Analytical, dough rheological and baking studies of optimizing the wheat flour baking test, Rapid-Mix-Test. 2. Part : Procedure of the optimized Rapid-Mix-Test Getreide, Mehl und Brot (1972) 40(4): 116-118
Schraderolms, B.; Seibel, W.; Pfeilsticker, K. 1986: Analytische, teigrheologische und backtechnische Studien zur Optimierung des Weizen-Backversuches, Rapid-Mix-Test - Etude bromatologique, rhéologique et technologique d'optimisation du «Rapid-Mix-Test» de panification du blé. II. Travaux préliminaires pour l'optimisation des essais de panification par le «Rapid-mix-test» - Analytical, dough rheological and baking studies of optimizing the wheat flour baking test, Rapid-Mix-Test. 2. Part : Procedure of the optimized Rapid-Mix-Test Getreide, Mehl und Brot (1972) 40(4): 116-118
Mathieu, E.; Gallois, Y.; Cortey, M.L.; Marcais, J. 1990: Chemiluminescence immunoassay kit with acridinium-ester-labeled antibody for assay of choriogonadotropin in serum Clinical Chemistry 36(1): 157
Emancipator, K.; Bock, J.L.; Burke, M.D. 1990: Diagnosis of ectopic pregnancy by the rate of increase of choriogonadotropin in serum: diagnostic criteria compared Clinical Chemistry 36(12): 2097-2101
Biffl, H.; Goebel, R.; Leb, G. 1979: The clinical significance of radioimmunologically determined serum bile acids as a new liver function test and the development of a new intravenous sulfolithoglycocholic acid (SLGC) stimulation test Acta Medica Austriaca 6(4): 113-120
Martin, M.; Van Hoof, V.; Couttenye, M.; Prove, A.; Blockx, P. 1997: Analytical and clinical evaluation of a method to quantify bone alkaline phosphatase, a marker of osteoblastic activity Anticancer Research 17(4b): 3167-3170
Prudnik, I.M.; Lukicheva, T.I.; Antonov, V.S.; Steklova, I.V. 1989: Adaptation of a micromethod for determining glucose in the FP-900 analytical system Laboratornoe Delo 7: 25-27
Rapoport, S.I.; Shubina, N.A. 2014: 13-year period of application of the 13C-urease breath test for determining Helicobacter pylori in Russian clinical practice Klinicheskaia Meditsina 92(11): 59-64