Scanning electron microscopic study of rabbit ovarian follicle microvasculature using resin injection-corrosion casts
Kanzaki, H.; Okamura, H.; Okuda, Y.; Takenaka, A.; Morimoto, K.; Nishimura, T.
Journal of Anatomy 134(Pt 4): 697-704
1982
ISSN/ISBN: 0021-8782 PMID: 7130034 Document Number: 187059
The microvasculature of rabbit ovarian follicles was investigated three dimensionally with resin casting/SEM technique. Characteristic vascular patterns were revealed around the follicles of various developing stages. It is suggested that increased capillary permeability and congestion of the blood stream occurred just prior to ovulation.
Document emailed within 1 workday
Related Documents
Macchiarelli, G.; Nottola, S.A.; Picucci, K.; Stallone, T.; Motta, P.M. 1998: The microvasculature of the corpus luteum in pregnant rabbit. a scanning electron microscopy study of corrosion casts Italian Journal of Anatomy and Embryology 103(4 Suppl 1: 191-202Kanzaki, H.; Okamura, H.; Okuda, Y.; Takenaka, A.; Morimoto, K.; Nishimura, T. 1981: Scanning electron microscopic observations of microcorrosion casts for rabbit ovarian vasculature before ovulatory stimulus Nihon Sanka Fujinka Gakkai Zasshi 33(1): 11-18
Pannarale, L.; Onori, P.; Borghese, F.; Conte, D.; Gaudio, E. 2007: Three-dimensional organization of the hepatic artery terminal branches: a scanning electron microscopic study of vascular corrosion casts of rat liver Italian Journal of Anatomy and Embryology 112(1): 1-12
Khimmaktong, W.; Petpiboolthai, H.; Panyarachun, B.; Anupunpisit, V. 2012: Study of curcumin on microvasculature characteristic in diabetic rat's liver as revealed by vascular corrosion cast/scanning electron microscope (SEM) technique Journal of the Medical Association of Thailand 95(Suppl 5): S133-S141
Ueno, H. 1976: Studies on the radial peripapillary capillaries (RPCs). (2) Scanning electron microscopic studies on the corrosion casts of the RPCs Nippon Ganka Gakkai Zasshi 80(5): 281-292
Grunt, T.; Lametschwandtner, A.; Staindl, O. 1982: Angioarchitecture of the retroauricular skin in humans. Scanning electron microscope studies of corrosion casts Hno 30(11): 420-425
Tay, F.R.; Gwinnett, A.J.; Wei, S.H. 1996: The overwet phenomenon: a scanning electron microscopic study of surface moisture in the acid-conditioned, resin-dentin interface American Journal of Dentistry 9(3): 109-114
Ohtani, O.; Ohtsuka, A.; Owen, R.L. 1986: Three-dimensional organization of the lymphatics in the rabbit appendix. A scanning electron and light microscopic study Gastroenterology 91(4): 947-955
Seki, R. 1988: Scanning electron microscopic observations on vascular casts of ciliary processes in normal and topical epinephrine-treated rats Japanese Journal of Ophthalmology 32(3): 288-296
Hayashi, K. 1992: Three-dimensional organization of the cartilage canal--a scanning electron-microscopic study by vascular cast of the rabbit's femoral head Nihon Seikeigeka Gakkai Zasshi 66(5): 548-559
Johnston, W.H.; Latta, H. 1972: Acute focal glomerulonephritis in the rabbit induced by injection of Saccharomyces cerevisiae. An electron microscopic study Laboratory Investigation; A Journal of Technical Methods and Pathology 26(6): 741-754
Leonhardt, H. 1976: The cerebrospinal fluid contact processes in the central canal of the spinal cord. a scanning and transmission electron microscopic study of the rabbit Zeitschrift für Mikroskopisch-Anatomische Forschung 90(1): 1-15
Sugino, K.; Miki, T. 1986: Observation of the ocular tissues using the cracking method. 4. Scanning electron microscopic study of endothelial cells of the retinal artery and vein in the albino rabbit Nippon Ganka Gakkai Zasshi 90(3): 423-433
Sugita, A. 1978: Scanning electron microscopic studies of the normal ocular tissues. 2. Scanning and transmission electron microscopic studies of the melanocytes in the iris stroma of Japanese monkey Nippon Ganka Gakkai Zasshi 82(11): 786-797
Matsushima, M.; Miki, T. 1982: Observation of the ocular tissues using the cracking method. 3. Scanning electron microscopic study of the inner cell surface of the rhesus monkey choroidal vessels using the stylene-resin cracking method Nippon Ganka Gakkai Zasshi 86(10): 1594-1604
Berthou, J.; Chrétien, F.C.; Driguez, P.A. 2003: Degradation of copper IUDs in utero. the process of metallic corrosion. a scanning electron microscope study Gynecologie Obstetrique and Fertilite 31(1): 29-42
Julkunen, H. 1971: Scanning electron microscopic study in scleroderma Annales Medicinae Experimentalis et Biologiae Fenniae 49(4): 180-185
Iványi, B.; Farkas, Z.; Bohus, K.; Lantos, J.; Ormos, J. 1984: Scanning electron microscopic study of experimental pyelonephritis Morphologiai Es Igazsagugyi Orvosi Szemle 24(2): 81-87
Stofft, E.; Graf, J. 1983: Scanning electron microscopic study of hyalin joint cartilage Acta Anatomica 116(2): 114-125
Leithner, C.; Piza-Katzer, H.; Kruzik, P.; Winter, M.; Mayr, W.R.; Stachelberger, H.; Sinzinger, H. 1978: Scanning electron microscopic study of hyperacute rejection in the inbred rat Proceedings of the European Dialysis and Transplant Association. European Dialysis and Transplant Association 15: 330-334