Instaneous changes in the radial artery blood flow under different physiological conditions

Oliva, I.; Levy, B.I.; Martineaud, J.P.

Physiologia Bohemoslovaca 29(4): 333-336

1980


ISSN/ISBN: 0369-9463
PMID: 6448419
Document Number: 158736
Using a Doppler pulse flowmeter we measured the blood flow in the radial artery at rest and during physical exercise and various other stimuli (arithmetical calculations, electrical stimulation, deep inspiration). The mean resting flow in the radial artery was 0.66 ml/s. Every stimulus was instantaneously followed by a drop in the blood flow to a minimum value; there was no significant differences between these values. The results demonstrate that the new, non-invasive apparatus can be used to study quick changes in the blood flow not detected by routine non-invasive methods.