Morphological and biochemical examinations of different suture materials in colon anastomosis in the rat

Nöthiger, F.

Helvetica Chirurgica Acta 46(1-2): 213-218

1979


ISSN/ISBN: 0018-0181
PMID: 468572
Document Number: 147470
Histological, mechanical and biochemical examinations in the one layer colon anastomosis of the rat have shown that the synthetic resorbable suture material as Dexon and Vicryl are as good or even better than silk or catgut chromic. The most favourable histological reaction is observed with Dexon. Collagenolytic activity and collagen content are not influenced by the suture material during the first 14 postoperative days.