Blood viscosity and triglyceridemia. Findings using a co-axial cylindrical viscosimeter at low "shear rates"
Bartoli, V.; Pasquini, G.; Dorigo, B.
Minerva Medica 68(44): 3081-3086
1977
ISSN/ISBN: 0026-4806 PMID: 917327 Document Number: 110811
Examination of blood viscosity at low shear rates using a co-axial cylinder viscometer showed a significant difference between the means of values observed in hypertrigliceridemic patients compared with that of control subjects. This result differs from what has been reported by most workers although generally greater shear rates have been used. Calculation of the "r" coefficient and plotting of the regression line for each shear rate showed that there is no linear correlation between blood viscosity and triglyceridaemia, whose variations occur quite independently. It is suggested that the absence of a correlation between the two parameters examined may depend on various factors, of which the most important are those pertaining to the rheological properties of red blood cells and to the structure and chemical and physical characteristics of the triglyceride molecule and of the lipoproteins and chylomicrons which transport them.