Drug interference in laboratory testing
Forman, D.T.; Young, D.S.
Annals of Clinical and Laboratory Science 6(3): 263-271
1976
ISSN/ISBN: 0091-7370 PMID: 942184 Document Number: 96907
Characteristic problems in the interpretation of laboratory data when a drug or its metabolite interferes with a laboratory procedure are reviewed. Various mechanisms of interference (physical, chemical, pharmacological and drug-drug interaction) are discussed. The role of a computerized drug-test interference file in assisting in the prediction and interpretation of apparent test results is described.
Document emailed within 1 workday
Related Documents
Nishikaze, O. 1975: Drug-drug interaction and drug-induced interference with clinical laboratory test procedures--chairman's introductory remarks Rinsho Byori. Japanese Journal of Clinical Pathology 23(2): 75Tarnow, E. 2005: Proactive interference, retroactive interference--what about self-interference? a new interpretation of the recency-primacy shift Medgenmed: Medscape General Medicine 7(1): 5
Halsey, J.F. 2000: Direct access testing in the clinical laboratory: should laboratories offer testing services directly to the consumer? Clinical Leadership and Management Review: the Journal of Clma 14(6): 261-266
Massambu, C.; Mwangi, C. 2009: The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system American Journal of Clinical Pathology 131(6): 861-866
Bowie, L.J.; Kirkpatrick, P.B.; Dohnal, J.C. 1987: Thyroid-function testing with the TDx: interference from endogenous fluorophore Clinical Chemistry 33(8): 1467
Lippi, G. 2012: Interference Studies: Focus on Blood Cell Lysates Preparation and Testing Clinical Laboratory 58(3-4): 351-355
Tukhas, V.A.; Pozhidaev, S.V. 2001: Experience in designing equipment for testing technical means by the interference stability requirements Meditsinskaia Tekhnika 3: 12-14
Goldmann, B.U.; Langenbrink, L.; Matschuck, G.; Heeschen, C.; Kolbe, S.-Busch; Niederau, C.; Katz, N.; Wenserit, C.; Heiko-Lestin, G.; Blinker, K.; Kuhn, E.; Tebbe, U.; Spanuth, E.; Hamm, C.W. 2004: Quantitative Bedside Testing of Troponin T: Is it Equal to Laboratory Testing? The Cardiac Reader Troponin T (CARE T) Study Clinical Laboratory 50(1-2): 1-10
Cone, E.J. 2006: Oral fluid testing: new technology enables drug testing without embarrassment Journal of the California Dental Association 34(4): 311-315
Grötsch, H.; Hajdu, P. 1987: Interference by the new antibiotic cefpirome and other cephalosporins in clinical laboratory tests, with special regard to the "Jaffé" reaction Journal of Clinical Chemistry and Clinical Biochemistry 25(1): 49-52
Lintel, N.J.; Brown, D.K.; Schafer, D.T.; Tsimba-Chitsva, F.M.; Koepsell, S.A.; Shunkwiler, S.M. 2017: Use of standard laboratory methods to obviate routine dithiothreitol treatment of blood samples with daratumumab interference Immunohematology 33(1): 22-26
Mitarai, S. 2005: The external quality assessment for Mycobacterium tuberculosis drug susceptibility testing by proficiency testing panel to the commercial laboratories Kekkaku: 80(4): 349-358
Purandare, B. 2015: Successful Management of Highly Drug-Resistant Tuberculosis with Individualized Drug Susceptibility Testing Journal of the Association of Physicians of India 63(7): 94-95
Yosselson-Superstine, S. 1982: Drug interference with clinical tests performed by a 20-channel computerized autoanalyzer American Journal of Hospital Pharmacy 39(5): 848-849
Lou, J.-y.; Peng, Z.-l.; Zheng, Y.; Wang, H.; He, B.; Wang, H.-j. 2006: Reversal of multi-drug resistance in ovarian cancer cell by RNA interference Zhonghua Fu Chan Ke Za Zhi 41(6): 413-416
Siest, G.; Delwaide, P.; Malya, P.A.G.; Breuer, H.; Galteau, M.M.; Salway, J.G.; Tognoni, G.; Tryding, N. 1988: International Federation of Clinical Chemistry, Scientific Committee: Drug interferences and drug effects in clinical chemistry. Part 6. Laboratory tests in monitoring drug administration Journal of Clinical Chemistry and Clinical Biochemistry 26(3): 181-186
Wright, B.T.; Robinson, L.A. 1982: Pediatric drug information: tests for glucose in the urine: understanding test specificity and interference Pediatric Nursing 8(1): 44-45
Irnich, W.; de Bakker, J.M.; Bisping, H.J. 1974: Interference with cardiac pacemakers. Sources of interference, pacemaker behaviour, counteractions Biomedizinische Technik. Biomedical Engineering 19(5): 193-204
Fischer, P.M. 1991: Laboratory testing in the 1990s Journal of Family Practice 33(5): 453-454
Young, D.S. 1978: Clinical laboratory testing Mayo Clinic Proceedings 53(7): 475-476