Evaluation of HBsAg detection methods from AABB-CAP survey data

Polesky, H.F.; Taswell, H.F.

American Journal of Clinical Pathology 63(6 Suppl): 1002-1006

1975


ISSN/ISBN: 0002-9173
PMID: 807099
Document Number: 89817
The results obtained by referees and participants on nine HBsAg survey panels are reviewed. Comparison of the two methods used by the majority of participants, counterelectrophoresis (CEP) and radioimmunoassay (RIA), shows that the latter consistently identifies a larger number of the positive samples. The RIA results show some problems with specificity, but these were reduced during the two-year period. The performance of the participants using CEP improved during the two-year period. The Survey documents the change in popularity of the methods.