Accuracy of the mammographic report category according to BIRADS

Hirunpat, S.; Tanomkiat, W.; Khojarern, R.; Arpakupakul, N.

Journal of the Medical Association of Thailand 88(1): 62-65

2005


ISSN/ISBN: 0125-2208
PMID: 15960219
Document Number: 8188
To determine the accuracy and predictive value of the mammographic report according to the BIRADS categories in Songklanagarind University Hospital. Mammograms of 1000 women who came to Songklanagarind University Hospital from June 1998 to September 1999 were reported and placed in category 1 for negative results, category 2 for benign lesions, category 3 for probably benign lesions, category 4 for suspicious lesions and category 5 for highly suspicious lesions. Accuracy was determined by either histology or by unchanged follow-up mammography within 24 months. The total accuracy was 97.8%, sensitivity 62.5% and specificity 98.1%.