Use of a 10,600-nm CO2 Laser Mandibular Vestibular Extension in a Patient with a Chromosomal Abnormality

Levine, R.; Vitruk, P.

Compendium of Continuing Education in Dentistry 37(8): 527-533;quiz 534

2016


ISSN/ISBN: 2158-1797
PMID: 27608196
Document Number: 689691
Vestibuloplasty involves a series of surgical procedures designed to restore alveolar ridge height by lowering the muscles attached to the buccal, labial, and lingual aspects of the jaws. The technique is indicated in cases of insufficient vestibular depth that may result from atrophy of the alveolar ridge and/or high attachment of muscle or movable mucosa. This article focuses on a carbon dioxide (CO2) laser vestibular extension procedure performed in a patient with Klinefelter syndrome, which is caused by a chromosomal abnormality. The 10,600-nm CO2 laser is shown to offer several advantages over a conventional scalpel and other laser wavelengths for soft-tissue pre-prosthetic surgery, including vestibular extension.