Reimplantation Technique: a new Approach to Increase Aortic Valve Coaptation
Antona, C.; Romagnoni, C.; Contino, M.; Mangini, A.
Journal of Heart Valve Disease 24(3): 290-291
2015
ISSN/ISBN: 0966-8519 PMID: 26901897 Document Number: 684908
The reimplantation technique is one of the most popular valve-sparing procedures. Previously published in-vitro studies have demonstrated the success of the aortic interleaflets triangle reshaping approach in increasing the coaptation surface. An alternative positioning of the pledgeted stitches used in the proximal suture line of the David operation is proposed to simultaneously stabilize the annulus and improve the valve functional reserve in case of annulo-aortic ectasia due to dilation of the interleaflet triangles.
Document emailed within 1 workday
Related Documents
Tabayashi, N.; Kitamura, S.; Taniguchi, S.; Kobayashi, S.; Niwaya, K.; Yoshikawa, Y. 1997: One-stage replacement of the entire thoracic aorta with aortic valve reimplantation technique--a reoperation for a Marfan patient with annulo-aortic ectasia and chronic aortic dissection of DeBakey type I Nihon Kyobu Geka Gakkai 45(9): 1644-1648Graeter, T.P.; Fries, R.; Aicher, D.; Reul, H.; Schmitz, C.; Schäfers, H.-J. 2006: In-vitro comparison of aortic valve hemodynamics between aortic root remodeling and aortic valve reimplantation Journal of Heart Valve Disease 15(3): 329-335
Takemura, T.; Shimamura, Y.; Sakaguchi, M.; Tsuda, Y.; Iwasa, S. 2003: Aortic valve replacement with a freestyle stentless valve using the modified subcoronary technique and hemiarch replacement for bicuspid aortic valve and ascending aortic aneurysma; report of a case Kyobu Geka. Japanese Journal of Thoracic Surgery 56(5): 411-413
Majak, P.; Lunde, I.G.; Hasic, A.K.; Husebye, T.; Christensen, G.; Tønnessen, T.; Bjørnstad, J.L. 2015: Reduced visfatin levels in aortic stenosis increase after aortic valve replacement and may contribute to reverse left ventricular remodelling Journal of Cardiovascular Surgery 56(3): 483-492
Wariishi, S.; Kanemitsu, N.; Okabe, M.; Nakamura, T.; Kitamura, F. 2000: Aortic valve replacement for aortic valve stenosis due to congenital bicuspid aortic valve with abnormal positioning of coronary orifice, pseudotendon, and persistent left superior vena cava, report of a case Kyobu Geka. Japanese Journal of Thoracic Surgery 53(7): 586-589
Hata, T.; Fujiwara, K.; Furukawa, H.; Tsushima, Y.; Yoshitaka, H.; Kuinose, M.; Minami, H.; Ishida, A.; Tamura, K.; Totsugawa, T.; Kanemitsu, H.; Ozawa, M. 2006: Surgical technique of aortic valve replacement for small aortic annulus in elderly patients Kyobu Geka. Japanese Journal of Thoracic Surgery 59(4): 283-287
Mashiko, K.; Shimizu, S.; Okuyama, H.; Mizuno, A.; Suzuki, K.; Nakano, M.; Kurosawa, H. 1994: A technique of successfully performing an annuloplasty for narrowed aortic valvular annulus in aortic valve replacement Nihon Kyobu Geka Gakkai 42(9): 1267-1271
Asano, R.; Nakano, K.; Kodera, K.; Sato, A.; Kataoka, G.; Tatsuishi, W.; Kubota, S.; Namiki, S.; Suzuki, S. 2015: Ascending-descending Aortic Bypass and Aortic Valve Replacement for Aortic Coarctation with Bicuspid Aortic Valve and an Aberrant Right Subclavian Artery;Report of a Case Kyobu Geka. Japanese Journal of Thoracic Surgery 68(9): 777-779
Osumi, M.; Matsueda, T.; Kurushima, A.; Otani, T.; Fukumura, Y. 2010: Aortic dissection after aortic valve replacement for bicuspid aortic valve complicated with ascending aortic dilatation; report of a case Kyobu Geka. Japanese Journal of Thoracic Surgery 63(3): 237-240
Wazir, H.Dil.; Qureshi, A.Usaid.; Hyder, S.Najam.; Sadiq, M. 2019: Immediate And Midterm Results Of Balloon Aortic Valvuloplasty In Children With Aortic Valve Stenosis With Special Reference To Dysplastic Aortic Valve Journal of Ayub Medical College Abbottabad: Jamc 31(4): 517-521
Tran-Quang-Hoa; Smolinsky, A.; Neufeld, H.N.; Goor, D.A. 1986: Dysplastic aortic valve with absence of aortic valve cusp: an unreported cause of congenital aortic insufficiency Journal of Thoracic and Cardiovascular Surgery 91(3): 471-472
King, W.L.; Ersek, R.A.; Rozelle, L.T.; Petersen, E.D.; Beisang, A.; Lillehei, R.C. 1971: Technique for predicting the effectiveness of aortic valve preservation methods Surgery 69(6): 863-869
Kobayashi, T.; Katoh, T.; Hamano, K.; Mikamo, A.; Okada, H.; Goura, H.; Zenpo, N.; Esato, K. 2000: J-sternotomy approach for aortic valve reoperation Kyobu Geka. Japanese Journal of Thoracic Surgery 53(12): 1041-1043
Belov, I.V.; Stepanenko, A.B.; Gens, A.P.; Babalian, G.V.; Buravikhina, T.A. 1998: Aortic valve prosthesis implantation from a mini approach Vestnik Khirurgii Imeni I. I. Grekova 157(3): 47-49
Botkin, N.F.; Aurigemma, G.P. 2004: Aortic valve disease: a practical clinical approach Minerva Cardioangiologica 52(4): 263-272
Spillner, J.; Börgermann, J.; Reppenhagen, G.; Er-Xiong, L.; Reidemeister, J.ür.C.; Friedrich, I. 2005: An experimental approach to reversible 'endovascular aortic valve placement' Journal of Heart Valve Disease 14(4): 546-550
Jørgensen, T.H.øj.; Thygesen, J.B.; Thyregod, H.G.; Svendsen, J.H.; Søndergaard, L. 2015: New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation: a concise review Journal of Invasive Cardiology 27(1): 41-47
Contamin, C.; Denis, B.; Micoud, M.J.; Avezou, F.; Descours, C.; Marty, B.; Latreille, R.; Barrie, J. 1973: Aortic valve prosthesis and aorto-coronary bypass. Value of preoperative coronarography for the surgical treatment of aortic valve lesions La Nouvelle Presse Medicale 2(28): 1910
Mura, A.; Konieczyńska, Młgorzata.; Przewłocki, T.; Kabłak-Ziembicka, A.; Płazak, W.; Pasowicz, Mław.; Podolec, P.; Tracz, Wława. 2004: Correlation between the severity of aortic valve stenosis by Doppler echocardiography (DE) and the magnitude of calcium deposits in aortic valve by MSCT Acta Cardiologica 59(2): 216-217
Pozzoli, A.; Taramasso, M.; Haager, P.; Miura, M.; Gülmez, G.ök.; Lin, S.-I.; Gavazzoni, M.; Rickli, H.; Maisano, F. 2019: Clinical Outcomes in Patients with Severe Aortic Valve Stenosis Treated with a Portico Transcatheter Aortic Valve System Surgical Technology International 34: 331-338