Surgical technique of aortic valve replacement for small aortic annulus in elderly patients

Hata, T.; Fujiwara, K.; Furukawa, H.; Tsushima, Y.; Yoshitaka, H.; Kuinose, M.; Minami, H.; Ishida, A.; Tamura, K.; Totsugawa, T.; Kanemitsu, H.; Ozawa, M.

Kyobu Geka. Japanese Journal of Thoracic Surgery 59(4): 283-287

2006


ISSN/ISBN: 0021-5252
PMID: 16613145
Document Number: 597780
Recent reports have shown that aortic valve replacement in elderly patients over 65 years with atherosclerotic aortic stenosis and a small aortic annulus is possible by using a small sized bioprosthesis (Carpentier-Edwards pericardial valve). Here we present out surgical technique. Firstly, the native calcified aortic valve was removed completely to gain total exposure of the surrounding aortic root and sinus of Valsalva like Bentall procedure. Secondly, a small sized bioprosthesis was implanted with intermittent noneverting mattress 2-0 sutures with spaghetti and small polytetrafluoroethylene (PTFE) felt. Aortic annulus is the dilated by inserting Hegar dilator sizing from 25 to 27 mm. Therefore, aortic valve replacement for small aortic annulus in intra- or supra-annular position should be easily accomplished. Good surgical results and hemodynamic state were achieved in 25 consecutive cases using this technique.