First experience of a polyurethane foam composition "Locus" use to stop intra-abdominal hemorrhage as a result of liver damage of V degree. (An experimental study)
Reva, V.A.; Litinskii, M.A.; Denisov, A.V.; Sokhranov, M.V.; Telitskii, S.Yu.; Samokhvalov, I.M.
Voenno-Meditsinskii Zhurnal 336(4): 32-39
2015
ISSN/ISBN: 0026-9050 PMID: 26454936 Document Number: 680504
Today self-expanding polymers are considered as the most promising as means for intracavitary hemostasis in case of continuing bleeding after trauma. Testing of domestic open-cell polyurethane foam composition "Locus" was carried out on the developed experimental model simulating liver trauma of V degree. After damaging 6 experimental rabbits were injected intraperitoneally with 80 ml of the composition. 5 experimental rabbits were included into to control group (haemostatic agent was not given). Estimated blood loss was 111-124 ml. The two-hour survival rate didn't differ significantly: 3 animals survived in the experimental group; 2 animal survived in the control. Despite the 3-4-fold widening of the foam, due to open cells it absorbed 72.6 +/- 8.3 g of blood. Thus, open-cell polyurethane foam intraperitoneal administration of the composition didn't provide a temporary intra-abdominal hemostasis in liver. In order to enhance the hemostatic effect it requires changing the formulation of the polyurethane composition. For a more accurate assessment of the results it is neccessary to perform additional researches on larger animals.