Bone reaction to mechanical impulses. IX. Significance of surface pressures for the modeling of diaphysis
Hert, J.
Gegenbaurs Morphologisches Jahrbuch 118(3): 351-368
1973
ISSN/ISBN: 0016-5840 PMID: 4697286 Document Number: 67598
Document emailed within 1 workday
Related Documents
Domazet, N.; Starović, D.; Nedeljković, R. 1999: Biomechanical significance of the acetabular roof and its reaction to mechanical injury Srpski Arhiv Za Celokupno Lekarstvo 127(11-12): 359-364Kübler, N.; Urist, M.R. 1990: Bone morphogenetic protein-mediated interaction of periosteum and diaphysis. Citric acid and other factors influencing the generation of parosteal bone Clinical Orthopaedics and Related Research 258: 279-294
Hert, J.; Sklenská, A.; Lisková, M. 1971: Reaction of bone to mechanical stimuli. 5. Effect of intermittent stress on the rabbit tibia after resection of the peripheral nerves Folia Morphologica 19(4): 378-387
Brizzi, E.; Gremigni, D. 1974: On the intra-osseous vascularization of a human long-bone diaphysis Bollettino della Societa Italiana di Biologia Sperimentale 50(8): 537-540
Reckling, F.W.; Waters, C.H. 1980: Treatment of non-unions of fractures of the tibial diaphysis by posterolateral cortical cancellous bone-grafting Journal of Bone and Joint Surgery. American Volume 62(6): 936-941
Papajík, T.; Jedlicková, K.; Kriegová, E.; Jarosová, M.; Raida, L.; Faber, E.; Hubácek, J.; Vondráková, J.; Pikalová, Z.; Indrák, K. 2001: Polymerase chain reaction detection of cells carrying t(14;18) in bone marrow of patients with follicular and diffuse large B-cell lymphoma: the importance of analysis at diagnosis and significance of long-term follow-up Neoplasma 48(6): 501-505
Mannarino, F.; Sexson, S. 1989: The significance of intracompartmental pressures in the diagnosis of chronic exertional compartment syndrome Orthopedics 12(11): 1415-1418
Timoshenko, D.A.; Timoshenko, D.D.; Golovushikin, A.A. 2002: Mathematical modeling of the process of thermal action of the surface of human skin Meditsinskaia Tekhnika 1: 19-21
Smalley, K.; Kesavadas, T. 2005: Development of a method for surface and subsurface modeling using force and position sensors Studies in Health Technology and Informatics 111: 482-487
Thorén, K.; Aspenberg, P.; Thorngren, K.G. 1995: Lipid extracted bank bone. Bone conductive and mechanical properties Clinical Orthopaedics and Related Research 311: 232-246
Kogan, A.K.; Malov, V.P.; Kogan, E.A. 1981: Modeling myocardial infarct by applying dimethyl sulfoxide to the anterior surface of the heart Patologicheskaia Fiziologiia i Eksperimental'naia Terapiia 5: 71-74
Kuroda, T. 1995: Bone formation and mechanical properties of the cancellous bone defect site filled with hydroxyapatite granules Nihon Seikeigeka Gakkai Zasshi 69(10): 1037-1049
Shibata, Y.; Miyazaki, T. 2017: New methods for the evaluation of bone quality. Nanoindentation protocol for measurement of bone mechanical properties of material level Clinical Calcium 27(8): 1139-1145
Benhamou, C.L.; Lespessailles, E.; Royant, V. 1996: Bone structure and mechanical resistance of the bone tissue Presse Medicale 25(6): 249-254
Wu, Y.; Li, Y-Shi.; Bejan-Angoulvant, T.; Gueyffier, Fçois. 2011: Modeling of systolic blood pressure reaction to antihypertensive agents in people with hypertension Zhonghua Xin Xue Guan Bing Za Zhi 39(4): 309-314
Cordero de Troconis, M.I.; Pfaff, R.; Nichols, D. 1997: Molecular modeling of N-isopropyl lisergamides analogous to LSD using molecular mechanics and quantum mechanical calculations Acta Cientifica Venezolana 48(2): 85-90
Hilbig, H.; Kirsten, M.; Rupietta, R.; Graf, H.-L.; Thalhammer, S.; Strasser, S.; Armbruster, F.P. 2007: Implant surface coatings with bone sialoprotein, collagen, and fibronectin and their effects on cells derived from human maxillar bone European Journal of Medical Research 12(1): 6-12
Rubin, P.; Squire, L. 1959: Clinical concepts in bone modeling American Journal of Roentgenology, Radium Therapy, and Nuclear Medicine 82(2): 217-228
Moreno, A.H.; Burchell, A.R.; Reddy, R.V.; Panke, W.F.; Nealon, T.F. 1975: The hemodynamics of portal hypertension revisited: determinants and significance of occluded portal pressures Surgery 77(2): 167-179
Claes, L.; Burri, C. 1980: Reaction of cortical bone to stress concentration, influence of different types of notches and rate of deflection to bone strength Acta Orthopaedica Belgica 46(5): 623-629