Identification of irradiated abalone by ESR spectroscopy
Song, Y.; Wang, C.; Yang, Z.; Zhong, W.; Geng, J.; Lu, D.; Ding, Z.
Wei Sheng Yan Jiu 41(3): 480-484
2012
ISSN/ISBN: 1000-8020 PMID: 23050453 Document Number: 660870
To establish an analytical method for the detection and identification of irradiated abalone by electron spin resonance spectroscopy. Electron spin resonance (ESR) was used to study the spectral characteristics of abalone and the characteristic peak for quantitation. There were obvious different ESR spectra between unirradiated and irradiated abalone. The g factor for unirradiated abalone was 2.0055-2.0060, the g1 and g2 factor for irradiated abalone were (2.0027 +/- 0.0001) and (1.9994 +/- 0.0001), respectively. The ESR signal intensity of characteristic peak was positively correlated with absorbed dose in the range of 0.5 - 10 kGy, left peak was the characteristic peak for quantitation and the detection limit was < or = 0.5 kGy. It was difficult to quantitate when the absorbed dose was over 10 kGy. ESR characteristic peak and g factor were able to qualitatively determine the irradiation of abalone. ESR spectroscopy is an effective method to determine whether the abalone being irradiated or not.