Cure kinetics of composites using video imaging

Sharp, L.J.; Sy, A.; Rui, Y.; Suh, B.I.

American Journal of Dentistry 18(2): 141-144

2005


ISSN/ISBN: 0894-8275
PMID: 15973835
Document Number: 591678
To study the rate of curing, three composites, Heliomolar (Vivadent), Z100 (3M), and Renew (Bisco) were investigated Volumetric shrinkage was measured at 25 degrees C using the Acuvol with an RG610 red filter. The dynamic measurements were made in the single view mode. Detailed kinetic studies for Renew determined the effect of varying the light intensity (100mW - 500mW) and irradiation time (3 seconds - 30 seconds) on the rate of curing. A measurement of the gel time of composites and a kinetic constant is reported. ANOVA followed by a Fisher's LSD test and a Kruskall-Wallis test were used for analysis of the data. The gel times follow the order of Heliomolar > Renew > Z100 at 20 seconds and 500 mW. Irradiation time had no significant effect on the gel time of Renew. Light intensity had a significant effect on the gel time of Renew.

Document emailed within 1 workday
Secure & encrypted payments