The use of real time visual feedback in the treatment of patients with increased fundamental frequency of voice
Chernobel'skiĭ, S.I.
Vestnik Otorinolaringologii 2005(4): 18-19
2005
ISSN/ISBN: 0042-4668 PMID: 16091715 Document Number: 585966
To correct fundamental frequency (FF) in five juveniles with puberphonia and in five women with functional dysphonia, we used visual computer feedback (musical soft Circ FFT, Svante Granqvist). Visual computer control over FF alterations facilitated the above correction. This method is an additional tool to the armory of therapeutic measures to correct FF. It is especially useful for persons with tin ear.
Document emailed within 1 workday
Related Documents
Lindahl, B.; Andolf, E.; Ingvar, C.; Ranstam, J.; Willén, R. 2008: Adjuvant tamoxifen in breast cancer patients affects the endometrium by time, an effect remaining years after end of treatment and results in an increased frequency of endometrial carcinoma Anticancer Research 28(2b): 1259-1262Waibel, J.; Wulkan, A.Jared.; Rudnick, A. 2013: Prospective efficacy and safety evaluation of laser treatments with real-time temperature feedback for fungal onychomycosis Journal of Drugs in Dermatology: Jdd 12(11): 1237-1242
Westebring-van der Putten, E.P.; Lysen, W.W.; Henssen, V.D.; Koopmans, N.; Goossens, R.H.M.; van den Dobbelsteen, J.J.; Dankelman, J.; Jakimowcz, J. 2009: Tactile feedback exceeds visual feedback to display tissue slippage in a laparoscopic grasper Studies in Health Technology and Informatics 142: 420-425
2004: Real-time solutions provide real benefits for TDA member dentists Texas Dental Journal 121(6): 532-533
Bach, T. 2019: Real Kinds in Real Time: on Responsible Social Modeling The Monist 102(2): 236-258
Dempsey, J.L.; Seshadri, R.S.; Morley, A.A. 1985: Increased mutation frequency following treatment with cancer chemotherapy Cancer Research 45(6): 2873-2877
William, J. 2008: Real change is needed. McCain, Obama need to address fundamental shortcomings of our system Modern Healthcare 38(42): 30
Gawryszewski, L.G.; Thomaz, T.G.; Machado-Pinheiro, W.; Sant'Anna, A.N. 1994: Onset and offset of a visual cue have different effects on manual reaction time to a visual target Brazilian Journal of Medical and Biological Research 27(1): 67-73
Mahdieh, N.; Raeisi, M.; Shirkavand, A.; Bagherian, H.; Akbari, M.T.; Zeinali, S. 2010: Investigation of GJB6 Large Deletions in Iranian Patients Using Quantitative Real-time PCR Clinical Laboratory 56(9-10): 467-471
Vasey, F.B.; Kinsella, T.D. 1977: Increased frequency of leukocyte-reactive antinuclear antibody in patients with ankylosing spondylitis Journal of Rheumatology 4(2): 158-164
Zhou, D.-b.; Zhao, J.-z.; Wang, S.; Ni, M.; Wang, R.; Zhang, D.; Zhao, Y.-l. 2005: Application of intraoperative real-time ultrasound in the surgical treatment of cerebral arteriovenous malformation Zhonghua Yi Xue Za Zhi 85(24): 1688-1691
Korkmaz, C.; Ozcan, A.; Akçar, N. 2005: Increased frequency of ultrasonographic findings suggestive of renal stones in patients with ankylosing spondylitis Clinical and Experimental Rheumatology 23(3): 389-392
Zalecki, T.; Gorecka-Mazur, A.; Pietraszko, W.; Surowka, A.D.; Novak, P.; Moskala, M.; Krygowska-Wajs, A. 2013: Visual feedback training using WII Fit improves balance in Parkinson's disease Folia Medica Cracoviensia 53(1): 65-78
Borz, C.; Bara, T.J.; Bara, T.; Suciu, A.; Denes, M.; Borz, B.; Marian, D.; Muresan, S.; Bacarea, A.; Muresan, M.; Jimborean, G. 2017: Laparoscopic gastric plication for the treatment of morbid obesity by using real-time imaging of the stomach pouch Annali Italiani di Chirurgia 6: 392-398
Shoshina, I.I.; Shelepin, I.E.; Semenova, N.B. 2014: The frequency-contrast sensitivity of visual stimulus perception in patients with schizophrenia with the therapy of atypical and typical antipsychotic drugs Fiziologiia Cheloveka 40(1): 43-48
Xu, Z-min.; Fang, Z-Xiang.; Lai, D-Kun.; Song, H-Lang. 2007: Development of an embedded mobile terminal for real-time remote monitoring of out-of-hospital cardiac patients Zhongguo Yi Liao Qi Xie Za Zhi 31(3): 182-4 191
Sun, Y.-P.; Cheng, M.; Song, S.-L.; Zhang, X.-H.; Li, R. 2008: Study on the use of TaqMan Real-time PCR to detect genogroup i and Ii norovirus in oysters and patients' stool samples Zhonghua Liu Xing Bing Xue Za Zhi 29(6): 594-597
Savli, H.; Gluzman, D.F.; Sunnetci, D.; Zavelevich, M.P.; Sklyarenko, L.M.; Nadgornaya, V.A.; Koval, S.V. 2011: Quantitative real time PCR analysis of apoptosis-related gene expression in leukemias in Ukrainian patients Experimental Oncology 33(2): 104-106
Mestre, D.R.; Ewald, M.; Maiano, C. 2011: Virtual reality and exercise: behavioral and psychological effects of visual feedback Studies in Health Technology and Informatics 167: 122-127
Frehmann, T.; Niemann, A.; Ustohal, P.; Geiger, W.F. 2002: Effects of real time control of sewer systems on treatment plant performance and receiving water quality Water Science and Technology: a Journal of the International Association on Water Pollution Research 45(3): 229-237