Impact of horizontal approach in vertical program: continuous quality improvement of malaria and tuberculosis diagnostic services at primary-level medical laboratories in the context of HIV care and treatment program in Ethiopia
Marinucci, F.; Manyazewal, T.; Paterniti, A.D.; Medina-Moreno, S.; Wattleworth, M.; Hagembe, J.; Redfield, R.R.
American Journal of Tropical Medicine and Hygiene 88(3): 547-551
2013
ISSN/ISBN: 0002-9637 PMID: 23324221 DOI: 10.4269/ajtmh.12-0628Document Number: 266184
The use of standardized tools for continuous quality improvement of laboratory services is crucial to identify service gaps, plan targeted interventions, and prove successes. Laboratory quality improvement tools (LQITs) were developed and applied for 18 months at five health centers and one faith-based hospital laboratories in Southwest Showa Zone in Ethiopia to assess and monitor the quality of malaria and acid-fast bacilli (AFB) microscopy total testing processes. For the six laboratories, baseline malaria microscopy scores were 55%, 42%, 52%, 55%, 54%, and 61%. Similarly, baseline AFB microscopy scores were 49%, 41%, 46%, 58%, 44%, and 70%. On the sixth quarter for the first four laboratories and the fourth quarter for the last two laboratories, malaria microscopy scores were 89%, 88%, 88%, 90%, 88%, and 89%, whereas AFB microscopy scores were 90%, 88%, 89%, 95%, 88%, and 90%. All laboratories scored above 85% for both services at the end of interventions.