Iatrogenic subtle acute aortic dissection during coronary angioplasty for in-stent restenosis. Value of intravascular ultrasound for diagnosis and management
Alfonso, F.; Alvarez, L.; Almeria, C.
Journal of Invasive Cardiology 16(9): 511-513
2004
ISSN/ISBN: 1042-3931 PMID: 15353807 Document Number: 566979
A patient with a subtle, iatrogenic, type A aortic dissection following a coronary angioplasty is described. Intravascular ultrasound was useful to confirm the diagnosis of the confined aortic dissection and also to guide adequate stent coverage of its coronary entry door. Both transesophageal echocardiography and magnetic resonance imaging failed to detect any significant aortic wall abnormality.
Document emailed within 1 workday
Related Documents
Ohsawa, H.; Noike, H.; Kanai, M.; Hitsumoto, T.; Aoyagi, K.; Sakurai, T.; Sugiyama, Y.; Yoshinaga, K.; Kaku, M.; Matsumoto, J.; Iizuka, T.; Shimizu, K.; Takahashi, M.; Tomaru, T.; Sakuragawa, H.; Tokuhiro, K. 2003: Preventive effect of an antiallergic drug, pemirolast potassium, on restenosis after stent placement: quantitative coronary angiography and intravascular ultrasound studies Journal of Cardiology 42(1): 13-22Lanjewar, C.P.; Sharma, A.; Sheth, T. 2009: IVUS-guided management of late stent malaposition with peri-stent restenosis with coronary artery aneurysm following drug-eluting stent implantation (paxlitaxel-eluting stent) Journal of Invasive Cardiology 21(5): E87-E90
Xu, S.; Nomura, M.; Kurokawa, H.; Ando, T.; Kimura, M.; Ishii, J.; Hasegawa, H.; Kondo, T.; Tadiki, S.; Qi, P. 1995: Relationship between coronary angioscopic and intravascular ultrasound imaging and restenosis Chinese Medical Journal 108(10): 743-749
Di Luzio, V.; De Remigis, F.; De Curtis, G.; Paparoni, S.; Pecce, P.; Di Emidio, L.; Prosperi, F.; D'Aroma, A.; Balducelli, M.; Maresta, A. 1997: Coronary restenosis after optimal (stent-like) initial angiographic results obtained by traditional balloon angioplasty Giornale Italiano di Cardiologia 27(7): 645-653
Mudra, H. 1997: Intravascular ultrasound imaging in coronary angioplasty Der Internist 38(1): 56-63
Pawłowski, T.; Kulawik, T.; Rzezak, J.ła. 2008: Balloon angioplasty for the treatment of the drug-eluting stent restenosis in a patient with multivessel coronary artery disease and muscular bridge Kardiologia Polska 66(11): 1229-1231; Discussion 1232
O'Brien, E.R.; Glover, C.; Labinaz, M. 2001: Acute outcome with the flexicut directional coronary atherectomy catheter for the treatment of coronary in-stent restenosis Journal of Invasive Cardiology 13(9): 618-622
Goods, C.M.; Al-Shaibi, K.F.; Yadav, S.S.; Liu, M.W.; Negus, B.H.; Iyer, S.S.; Dean, L.S.; Jain, S.P.; Baxley, W.A.; Parks, J.M.; Sutor, R.J.; Roubin, G.S. 1996: Utilization of the coronary balloon-expandable coil stent without anticoagulation or intravascular ultrasound Circulation 93(10): 1803-1808
Foley, D.P.; Serruys, P.W. 1996: Fluvastatin for the prevention of restenosis after coronary balloon angioplasty: angiographic and methodological background of the fluvastatin angioplasty restenosis trial British Journal of Clinical Practice. Supplement 77a: 40-53
Alfonso, F.; García-Touchard, A.; López-Meneses, M.; García, P.; Pimentel, G.; Hernandez, R.; Bañuelos, C.; Escaned, J.; Sabaté, M.; Fernandez-Ortiz, A.; Macaya, C. 2001: Acute stent thrombosis visualized by intravascular ultrasound Journal of Invasive Cardiology 13(7): 531-534
Daitoku, K.; Fukui, K.; Tamo, W.; Taniguchi, S.; Itoh, K.; Minakawa, M.; Suzuki, Y.; Fukuda, I. 2006: Emergency small-sized stent placement following aortic true lumen obliteration of Stanford type B acute aortic dissection Kyobu Geka. Japanese Journal of Thoracic Surgery 59(6): 445-448
Burkhard-Meier; Füssl, R.; Weihrauch, M.; Kaspers, S.; Höpp, H.W.; Erdmann, E.; Sechtem, U. 1996: Lumen enlargement in coronary angioplasty: qualitative and quantitative analysis of vascular mechanisms with intravascular ultrasound Zeitschrift für Kardiologie 85(4): 281-289
LaBlanche, J.M.; Magy, J.M.; Pruvost, P.; Fourrier, J.L.; Gommeaux, A.; Bertrand, M.E. 1989: Predictive value of exercise-induced ST depression in the diagnosis of restenosis after coronary angioplasty Archives des Maladies du Coeur et des Vaisseaux 82(6): 871-875
Tamberella, M.R.; Yadav, J.S.; Bajzer, C.T.; Bhatt, D.L.; Abou-Chebl, A. 2004: Cutting balloon angioplasty to treat carotid in-stent restenosis Journal of Invasive Cardiology 16(3): 133-135
Bendok, B.R.; Hopkins, L.Nelson. 2004: Cutting balloon angioplasty to treat carotid in-stent restenosis Journal of Invasive Cardiology 16(6): A16; Discussion A16
Zimarino, M.; Ajani, A.E.; Marazia, S.; Pichard, A.D.; Satler, L.F.; De Caterina, R.; Barsotti, A.; Waksman, R. 2002: Influence of device selection on angiographic outcomes for the treatment of in-stent restenosis. A sub analysis from the Washington Radiation for In-Stent restenosis Trial (WRIST) Italian heart journal: official journal of the Italian Federation of Cardiology 3(4): 256-262
Uchida, T.; Kuroda, Y.; Yamashita, A.; Hamasaki, A.; Hirooka, S.; Nakai, S.; Kobayashi, K.; Sadahiro, M. 2019: Clinical Experience of Endovascular Stent-graft Treatment for Stanford Type A Acute Aortic Dissection Kyobu Geka. Japanese Journal of Thoracic Surgery 72(12): 976-983
Suda, H.; Watanabe, K.; Ohteki, H.; Natsuaki, M.; Itoh, T. 1989: A successful emergency operation of acute aortic dissection (DeBakey I) with aortic root rupture and right coronary avulsion Nihon Kyobu Geka Gakkai 37(4): 746-750
Sueda, T.; Watari, M.; Orihashi, K.; Shikata, H.; Matsuura, Y. 1999: Open stent-graft repair for acute type A aortic dissection with an intimal tear in the descending aorta Annals of Thoracic and Cardiovascular Surgery: Official Journal of the Association of Thoracic and Cardiovascular Surgeons of Asia 5(4): 273-275
Chandrasekar, B.; deGuise, P.; Doucet, S. 1999: Successful balloon angioplasty of in-stent restenosis of left internal mammary artery Journal of Invasive Cardiology 11(7): 447-449