Acute stent thrombosis visualized by intravascular ultrasound
Alfonso, F.; García-Touchard, A.; López-Meneses, M.; García, P.; Pimentel, G.; Hernandez, R.; Bañuelos, C.; Escaned, J.; Sabaté, M.; Fernandez-Ortiz, A.; Macaya, C.
Journal of Invasive Cardiology 13(7): 531-534
2001
ISSN/ISBN: 1042-3931 PMID: 11435641 Document Number: 534037
Subacute stent thrombosis is currently a rare but feared complication in patients undergoing coronary intervention. Intravascular ultrasound is a useful technique to guide stent implantation. However, its value in patients suffering from acute stent thrombosis has not been described. Herein, we present the intravascular ultrasound findings of a patient experiencing ongoing stent thrombosis and impending vessel closure.
Document emailed within 1 workday
Related Documents
Kristensen, T.S.; Kofoed, K.F.; Engstrom, T. 2008: Acute stent thrombosis after bifurcation stenting with the crush technique visualized with 64-slice computed tomography Journal of Invasive Cardiology 20(7): 364-366Alfonso, F.; Alvarez, L.; Almeria, C. 2004: Iatrogenic subtle acute aortic dissection during coronary angioplasty for in-stent restenosis. Value of intravascular ultrasound for diagnosis and management Journal of Invasive Cardiology 16(9): 511-513
Shen, L.; Wu, Y.-z.; Zhang, F.; Sun, A.-j.; Zhong, W.; Qian, J.-y.; Ge, J.-b. 2012: Intravascular ultrasound assessment of chitosan/heparin layer-by-layer self assembly coating stent on late stent malapposition and vessel remodeling in porcine model Zhonghua Xin Xue Guan Bing Za Zhi 40(7): 569-574
Kuribayashi, S.; Takamiya, M.; Homma, S. 1999: Intravascular ultrasound observations during iliac stent deployment International Angiology: a Journal of the International Union of Angiology 18(4): 263-270
Kume, T.; Waseda, K.; Ako, J.; Sakata, K.; Yamasaki, M.; Shimohama, T.; Tsujino, I.; Hasegawa, T.; Fitzgerald, P.J.; Honda, Y. 2012: Intravascular ultrasound assessment of postprocedural incomplete stent apposition Journal of Invasive Cardiology 24(1): 13-16
Aggarwal, K.; Gupta, V. 2007: Optimal stent expansion: is the eye of the beholder as good as intravascular ultrasound Journal of Invasive Cardiology 19(3): 106-108
Goods, C.M.; Al-Shaibi, K.F.; Yadav, S.S.; Liu, M.W.; Negus, B.H.; Iyer, S.S.; Dean, L.S.; Jain, S.P.; Baxley, W.A.; Parks, J.M.; Sutor, R.J.; Roubin, G.S. 1996: Utilization of the coronary balloon-expandable coil stent without anticoagulation or intravascular ultrasound Circulation 93(10): 1803-1808
Park, J.-S.; Kim, Y.-J.; Hong, G.-R. 2007: Thrombosis and acute myocardial infarction as consequences of very late stent malapposition after implantation of a drug-eluting stent Journal of Invasive Cardiology 19(6): E163-E165
Vavuranakis, M.; Papaioannou, T.G.; Katsarou, O.A.; Vrachatis, D.A.; Sanidas, E.A.; Siasos, G.; Kalogeras, K.I.; Schizas, D.; Stefanadis, C.I.; Tousoulis, D. 2016: Impact of atherosclerotic plaque components and their distribution on stent deployment: an intravascular-ultrasound virtual histology observational study Minerva Cardioangiologica 64(5): 507-516
Koo, B.-K.; Yamasaki, M.; Ako, J.; Waseda, K.; Honda, Y.; Fitzgerald, P.J.; Abizaid, A.; Whitbourn, R.J. 2008: Intravascular ultrasound analysis of small-vessel lesions treated with novel ultra-low profile, guidewire-based self-expanding stent system Journal of Invasive Cardiology 20(12): 647-650
Albiero, R.; Rau, T.; Schlüter, M.; Di Mario, C.; Reimers, B.; Mathey, D.G.; Tobis, J.M.; Schofer, J.; Colombo, A. 1997: Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions Circulation 96(9): 2997-3005
Ohsawa, H.; Noike, H.; Kanai, M.; Hitsumoto, T.; Aoyagi, K.; Sakurai, T.; Sugiyama, Y.; Yoshinaga, K.; Kaku, M.; Matsumoto, J.; Iizuka, T.; Shimizu, K.; Takahashi, M.; Tomaru, T.; Sakuragawa, H.; Tokuhiro, K. 2003: Preventive effect of an antiallergic drug, pemirolast potassium, on restenosis after stent placement: quantitative coronary angiography and intravascular ultrasound studies Journal of Cardiology 42(1): 13-22
Dai, J.; Lyu, S.; Song, X.; Liu, H.; Tian, R.; Chen, X.; Gei, C.; Zhou, Y.; Xu, F. 2014: Repeated sub-acute stent thrombosis: a case report Zhonghua Xin Xue Guan Bing Za Zhi 42(3): 254-255
Nomura, M.; Kurokawa, H.; Ishii, J.; Ando, T.; Ito, M.; Taga, S.; Mori, Y.; Naruse, H.; Hishida, H. 1999: The role of angioscopy and intravascular ultrasound imaging in acute coronary syndrome Journal of Cardiology 33(Suppl 1): 17-21
Mukhopadhyay, S.; Yusuf, J.; Mehta, V.; Nathani, S.; Tyagi, S. 2011: Acute thrombosis of drug eluting stent following protamine: a case report Indian Heart Journal 63(3): 291-292
Kato, C.; Matsuyama, H.; Kondo, T.; Nagasaka, A.; Koie, S.; Iwase, M.; Nomura, M.; Hishida, H. 1999: Clinical evaluation of acute and chronic pulmonary thromboembolism using intravascular ultrasound and angioscopy Journal of Cardiology 34(6): 317-324
Almasswary, A.A. 2009: Very late stent thrombosis in a bare-metal stent, 9 years after implantation Saudi Medical Journal 30(6): 847-850
Chen, J.P. 2007: Late angiographic stent thrombosis (LAST): the cloud behind the drug-eluting stent silver lining? Journal of Invasive Cardiology 19(9): 395-400
Lemesle, G.; Pinto Slottow, T.L.; Waksman, R. 2009: Very late stent thrombosis after bare-metal stent implantation: case reports and review of the literature Journal of Invasive Cardiology 21(2): E27-E32
Iida, Y.; Ohata, H.; Kito, K.; Kawamura, M.; Yamashita, M.; Ohta, S.; Iida, H. 2013: A case of late drug-eluting stent thrombosis during postoperative period after 5 years of stent implantation Masui. Japanese journal of anesthesiology 62(6): 724-727