Preferential extraction of hydrocarbons from fire debris samples by solid phase microextraction

Lloyd, J.A.; Edmiston, P.L.

Journal of Forensic Sciences 48(1): 130-134

2003


ISSN/ISBN: 0022-1198
PMID: 12570213
Document Number: 553094
Headspace analysis by extraction/GC-MS is a common method of detecting volatile hydrocarbon accelerants in fire debris samples. Solid-phase microextraction was tested to determine if there is selective extraction of chemically distinct compounds. It was found that both the polydimethylsiloxane (PDMS) and Carboxen/PDMS solid phase microextraction fibers show preferential extraction of aliphatic or aromatic compounds from the headspace depending on fiber type and temperature. The Carboxen/PDMS fiber type showed particular (although not exclusive) selectivity for extraction of aromatic hydrocarbons. Other experimental considerations of SPME are noted.