Comparison of biomechanical properties between human nasal periosteum and fascia

Zeng, Y.; Wu, W.; Yang, J.; Li, Z.; Yu, H.

Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 19(3): 389-391

2002


ISSN/ISBN: 1001-5515
PMID: 12557504
Document Number: 544269
There has been a lot of controversies on which layer the silastic implants should be inserted in the augmentation rhinoplasty, i.e. subperiosteal or deep subfascial. This study is to investigate the biomechanical properties of human nasal periosteum and deep fascia, including tensile strength, stress-strain and stress relaxation characters under uniaxial tension system. The periosteum is stronger in tensile strength than that of the fascia, but it is less elastic. Under a sudden increase of load, the periosteum relaxes far less than the fasia. Therefore, in view of biomechanics, the periosteum is thicker, tougher, stiffer and less relaxation than facia, thus has a better fixation effect.