Evaluation of biocompatibility on titanium-zicornium alloy

Zhang, Y.; Wang, Q.; Guo, T.

Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 18(1): 9-11

2001


ISSN/ISBN: 1001-5515
PMID: 11332126
Document Number: 526698
In this study, the general toxicity tests including cytotoxicity, haemolysis and oral mucous irratation of the Ti-Zr alloy were investigated. The results showed the level of cytotoxicity was grade 0, the haemolysis degree was 0.15% and no histomorphologic change was observed in the animals of Ti-Zr alloy groups. These data indicate that Ti-Zr alloy has good biocompatibility as a dental material.