Catheter cuff shaving using a novel technique: a rescue treatment for persistent exit-site infections
Tan, S.Y.; Thiruventhiran, T.
Peritoneal Dialysis International Journal of the International Society for Peritoneal Dialysis 20(4): 471-472
2000
ISSN/ISBN: 0896-8608 PMID: 11007382 Document Number: 523436
Document emailed within 1 workday
Related Documents
Casey, M.; Taylor, J.; Clinard, P.; Graham, A.; Mauck, V.; Spainhour, L.; Brown, P.; Burkart, J. 2000: Application of mupirocin cream at the catheter exit site reduces exit-site infections and peritonitis in peritoneal dialysis patients Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 20(5): 566-568Fukasawa, M.; Matsushita, K.; Tanabe, N.; Mochizuki, T.; Hara, T.; Takeda, M. 2002: A novel salvage technique that does not require catheter removal for exit-site infection Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 22(5): 618-621
Gourtzelis, N.; Margassery, S.; Bastani, B. 2005: Successful treatment of severe Mycobacterium fortuitum exit-site infection with preservation of the Tenckhoff catheter Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 25(6): 607-608
Ahmed, Z.; Choudhury, D.; Lee, J.; Girgis, H. 1997: The role of curettage in the care of persistent exit-site infection in CAPD patients Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 17(2): 195-197
Crabtree, J.H.; Fishman, A.; Siddiqi, R.A.; Hadnott, L.L. 1999: The risk of infection and peritoneal catheter loss from implant procedure exit-site trauma Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 19(4): 366-371
Al-Hilali, N.A.; Ninan, V.T.; Al-Humoud, H.A.; Nampoory, M.R.N.; Johny, K.V. 2005: Mupirocin once weekly reduces the incidence of catheter exit-site infection in peritoneal dialysis patients Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 25(1): 91-92
Keogh, A.M. 1996: Complications in peritoneal dialysis: peritonitis and exit-site infections Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 16(Suppl 1): S464-S467
Shimomura, A.; Tahara, D.; Tominaga, M.; Uchigiri, S.; Yamaguchi, Y.; Ishioka, H.; Nakahata, A. 1995: The effect of ultraviolet rays on the prevention of exit-site infections Advances in Peritoneal Dialysis. Conference on Peritoneal Dialysis 11: 152-156
Zurowska, A.; Kosiak, W.; Czarniak, P.; Bałasz, I.; Zagozdzon, I. 2000: Ultrasound of exit-site and tunnel infections in children on peritoneal dialysis Polski Merkuriusz Lekarski: Organ Polskiego Towarzystwa Lekarskiego 8(46): 297-298
Ferguson, B.J.; Tzamaloukas, A.H. 1988: Exit site infections in CAPD patients wearing tight clothes Anna Journal 15(3): 180-181
Freitas, C.; Rodrigues, A.; Carvalho, M.J.ão.; Cabrita, A.ón. 2009: Exit site infections: systematic microbiologic and quality control are needed Advances in Peritoneal Dialysis. Conference on Peritoneal Dialysis 25: 26-31
Davies, S.J.; Ogg, C.S.; Cameron, J.S.; Poston, S.; Noble, W.C. 1989: Staphylococcus aureus nasal carriage, exit-site infection and catheter loss in patients treated with continuous ambulatory peritoneal dialysis (CAPD) Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 9(1): 61-64
Hanslik, T.M.; Newman, L.; Tessman, M.; Morrissey, A.B.; Friedlander, M.A. 1994: Lack of correlation between nasal cultures positive for Staphylococcus aureus and the development of S. aureus exit-site infections: results unaffected by routine mupirocin treatment of nasal S. aureus carriage Advances in Peritoneal Dialysis. Conference on Peritoneal Dialysis 10: 158-162
Khanna, R.; Twardowski, Z.J. 1996: Recommendations for treatment of exit-site pathology Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 16(Suppl 3): S100-S104
Moysés-Neto, M.; Cherubini, A.; Batista, M.E.; Raspanti, E.O.; Vieira-Neto, O.M.; Nakagawa, B.; Conceição, A.M.; Feres, M.R.; Vannucchi, M.T. 1997: Foreign body granuloma at the exit site in patients on CAPD: use of 1% gentian violet as topical treatment Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 17(5): 509-511
Meiland, H.T.; Feder, E.; Rosenø, H. 1986: Episiotomy infections after shaving or cutting Ugeskrift for Laeger 148(39): 2481-2482
Nakajima, Y.; Arai, T.; Hatano, Y. 1987: Persistent atrial fibrillation during insertion of central venous catheter with the catheter-over-guidewire device Masui. Japanese Journal of Anesthesiology 36(7): 1123-1125
Sun, C.; Zhang, M.; Jiang, C. 2015: Vertical Tunnel-based Low-site Peritoneal Dialysis Catheter Implantation Decreases the Incidence of Catheter Malfunction American Surgeon 81(11): 1157-1162
Scheidweiler, K.B.; Plessinger, M.A. 2002: Use of a novel abdominal wrap for protection of indwelling catheter exit sites in sheep Contemporary Topics in Laboratory Animal Science 41(6): 24-26
Crabtree, J.H. 2005: Peritoneal catheter splicing for distant relocation of poorly selected exit sites Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis 25(2): 192-195