Aortic valve replacement with a stentless porcine aortic root bioprosthesis
Kikuchi, Y.; Sakurada, T.; Suzuki, T.; Obata, H.; Kusajima, K.
Kyobu Geka. Japanese Journal of Thoracic Surgery 53(4): 295-300
2000
ISSN/ISBN: 0021-5252 PMID: 10770056 Document Number: 521268
From April, 1999 to November, 1999, 8 patients underwent the aortic valve replacement using Medtronic Freestyle aortic root bioprosthesis. Mean age was 67.8 years old. Aortic valve etiology was as follows, AS: 1 case, AR: 2 cases, ASR: 3 cases, IE: 1 case, mechanical valve malfunction due to subvalvular pannus: 1 case. The implanted valve size was 25: 2 cases, 23: 3 cases, 21: 1 cases, 19: 2 cases. Surgical technique was subcoronary: 7 cases, full-root: 1 case. Post-op 2D-echo revealed tribial aortic valve incompetence in two cases because of size discrepancy between the aortic annulus and the ascending aorta. Pacemaker implantation was needed in 1 case because of the complete A-V block. In comparison with 5 cases of aortic valve replacement with Hancock II performed in same period, there were no significant differences about the implanted valve size and mean systolic pressure gradient, but the effective orifice area in Freestyle cases was significantly larger than Hancock II cases.