Aortic valve replacement with stentless bioprosthesis: operative methods and pitfalls
Morita, S.; Yasui, H.
Kyobu Geka. Japanese Journal of Thoracic Surgery 53(4): 305-309
2000
ISSN/ISBN: 0021-5252 PMID: 10770058 Document Number: 521077
Operative methods and pitfalls of aortic valve replacement using either Toronto SPV and Freestyle prosthesis were described. Precise transverse aortotomy, straight inflow-suture line, and outflow suture not obstructing coronary orifices are the points for the standard procedure. For bicuspid aortic valves, care should be taken for the anomaly of coronary orifices. Our experience with 24 consecutive cases indicated that oversizing of the prosthesis was possible in stentless bioprosthesis.
Document emailed within 1 workday
Related Documents
Fukui, S.; Matsumiya, G.; Matsue, H.; Sawa, Y. 2007: Stentless bioprosthesis for aortic valve replacement Nihon Geka Gakkai Zasshi 108(2): 73-79Sato, T.; Isomura, T.; Suma, H.; Horii, T.; Kobashi, T.; Kanemitsu, H. 2000: Aortic valve/root replacement using a stentless bioprosthesis (Medtronic Freestyle valve) Kyobu Geka. Japanese Journal of Thoracic Surgery 53(4): 301-304
Kikuchi, Y.; Sakurada, T.; Suzuki, T.; Obata, H.; Kusajima, K. 2000: Aortic valve replacement with a stentless porcine aortic root bioprosthesis Kyobu Geka. Japanese Journal of Thoracic Surgery 53(4): 295-300
David, T.E.; Pollick, C.; Bos, J. 1990: Aortic valve replacement with stentless porcine aortic bioprosthesis Journal of Thoracic and Cardiovascular Surgery 99(1): 113-118
Tsukiji, M.; Akasaka, T.; Wada, N.; Okahashi, N.; Kume, T.; Yoshitani, H.; Neishi, Y.; Watanabe, N.; Yoshida, K. 2004: Bilateral coronary ostial stenosis after aortic valve replacement with freestyle stentless bioprosthesis: a case report Journal of Cardiology 44(5): 207-213
Takemura, T.; Shimamura, Y.; Sakaguchi, M.; Tsuda, Y.; Iwasa, S. 2003: Aortic valve replacement with a freestyle stentless valve using the modified subcoronary technique and hemiarch replacement for bicuspid aortic valve and ascending aortic aneurysma; report of a case Kyobu Geka. Japanese Journal of Thoracic Surgery 56(5): 411-413
D'Onofrio, A.; Mazzucco, A.; Valfrè, C.; Zussa, C.; Martinelli, L.; Casabona, R.; Mazzola, A.; Gherli, T.; Badano, L.P.; Fabbri, A. 2011: Left ventricular remodeling, hemodynamics and early clinical outcomes after aortic valve replacement with the Pericarbon Freedom stentless bioprosthesis: results from the Italian Prospective Multicenter Trial Journal of Heart Valve Disease 20(5): 531-539
Vola, M.; Gerbay, A.; Campisi, S.; Thulane, C.; Fuzellier, F.ço. 2015: Aortic sutureless bioprosthesis implantation following degeneration of a SOLO stentless valve Journal of Heart Valve Disease 24(2): 214-216
Nyawo, B.; Graham, R.; Hunter, S. 2007: Aortic valve replacement with the Sorin Pericarbon Freedom stentless valve: five-year follow up Journal of Heart Valve Disease 16(1): 42-48
Botzenhardt, F.; Hoffmann, E.; Kemkes, B.M.; Gansera, B. 2007: Determinants of ascending aortic dimensions after aortic valve replacement with a stented bioprosthesis Journal of Heart Valve Disease 16(1): 19-26
Hofmann, S.; Franz, N.; Billion, M.; Kowalski, M.; Glauner, C.; Christmann, U.; Thale, J. 2009: Successful catheter-based valve-in-valve implantation for a regurgitant stentless bioprosthesis Journal of Heart Valve Disease 18(6): 713-716
Chambers, J.; Rimington, H.; Rajani, R.; Hodson, F.; Blauth, C. 2004: Hemodynamic performance on exercise: comparison of a stentless and stented biological aortic valve replacement Journal of Heart Valve Disease 13(5): 729-733
Zannis, K.; Joffre, J.ér.ém.; Czitrom, D.; Folliguet, T.; Noghin, M.; Lansac, M.N.E.; Mitchell-Heggs, L.; Debauchez, M.; Laborde, F. 2014: Aortic valve replacement with the perceval S bioprosthesis: single-center experience in 143 patients Journal of Heart Valve Disease 23(6): 795-802
Murakami, T.; Eishi, K.; Nakano, S.; Kobayashi, J.; Sasako, Y.; Isobe, F.; Kosakai, Y.; Kito, Y.; Kawashima, Y. 1996: Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results Journal of Heart Valve Disease 5(1): 45-49
Meyns, B.; Szecsi, J.; Flameng, W.; Daenen, W. 1994: Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: mid-term clinical results Journal of Heart Valve Disease 3(1): 66-70
Sintek, C.F.; Fletcher, A.D.; Khonsari, S. 1996: Small aortic root in the elderly: use of stentless bioprosthesis Journal of Heart Valve Disease 5(Suppl 3): S308-S313
Schlömicher, M.; Taghiyev, Z.; Al-Jabery, Y.; Lukas Haldenwang, P.; Markthaler, L.; Moustafine, V.; Maria Laczkovics, A.; Thomas Strauch, J.; Bechtel, M. 2017: Aortic Valve Replacement with the Labcor TLPB Supra Porcine Bioprosthesis: Intermediate Clinical and Echocardiographic Outcomes Journal of Heart Valve Disease 26(1): 90-97
Höfig, M.; Nellessen, U.; Mahmoodi, M.; Sievers, H.H.; Leyh, R.; Maurer, I.; Bernhard, A.; Heintzen, P.H.; Simon, R. 1992: Performance of a stentless xenograft aortic bioprosthesis up to four years after implantation Journal of Thoracic and Cardiovascular Surgery 103(6): 1068-1073
Linneweber, J.; Kossagk, C.; Rogge, M.L.; Dushe, S.; Dohmen, P.; Konertz, W. 2006: Clinical experience with the 3F stentless aortic bioprosthesis: one-year follow up Journal of Heart Valve Disease 15(4): 545-548
Hata, T.; Namba, H.; Sone, Y.; Imamaki, M.; Kuinose, M.; Taniguchi, G. 1990: Post-operative evaluation of a 17 mm diameter Björk-Shiley Monostrut prosthesis for aortic valve replacement--pressure gradient and effective valve area Nihon Kyobu Geka Gakkai 38(3): 518-522