Can mathematical modeling be used to determine blood flow and shear stress in vivo?
Kern, M.J.
Journal of Invasive Cardiology 11(11): 675
1999
ISSN/ISBN: 1042-3931 PMID: 10745460 Document Number: 509804
Document emailed within 1 workday
Related Documents
Zhao, L.; Huang, Y.; Li, J.; Huang, M. 1997: Postsurgical changes of the calculated wall shear stress in autogenous interpositional venous grafts by blood flow waveform analysis: clinical and experimental studies Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 14(1): 21-25Liasnikova, A.V.; Taran, V.M.; Markelova, O.A.; Dudareva, O.A.; Grishina, I.P. 2013: Mathematical modeling of stress in plasma coatings used in medicine Meditsinskaia Tekhnika 3: 28-30
Huang, A.; Sun, D.; Koller, A.; Kaley, G. 1998: Gender difference in flow-induced dilation and regulation of shear stress: role of estrogen and nitric oxide American Journal of Physiology 275(5): R1571-R1577
Zeng, Y.; Liu, X.; Lai, Y.; Huang, X.; Mao, B.; Gao, T.; Shen, Y. 2010: Numerical simulation of the distribution of shear stress on the bottom of parallel plate flow chamber under different inlet velocity conditions Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 27(4): 785-789
Belyaev, L.V.; Ivanchenko, A.B.; Zhdanov, A.V.; Morozov, V.V. 2015: Mathematical modeling of hemodynamic characteristics of blood pumps for pulsative ventricle assist systems Meditsinskaia Tekhnika 1: 17-20
Liu, X.; Wang, X.; Huang, H.; Chen, H. 2003: A biomechanical model for simulating the deformation of a leukocyte adhered to the surface of a blood vessel under steady shear flow Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 20(1): 30-34
Heys, J.J.; DeGroff, C.; Manteuffel, T.; McCormick, S.; Tufo, H. 2004: Modeling 3-D compliant blood flow with FOSLS Biomedical Sciences Instrumentation 40: 193-199
Edwards, M.R.; Lin, D.C.; Hughson, R.L. 2001: Modeling the interaction between perfusion pressure and CO2 on cerebral blood flow Advances in Experimental Medicine and Biology 499: 285-290
Spychała, A. 1979: Correction of a mathematical model of capillary blood flow determination by means of isotope markers Polski Przeglad Radiologii i Medycyny Nuklearnej 43(5): 296-298
Kizilova, N.N. 2006: Modeling of intraorgan arterial vasculatures. I. A stationary blood flow at low Reynolds numbers Biofizika 51(4): 733-737
Lanthier, T.; Miller, C.; McDonell, W.N.; Yager, J.A.; Roth, J.H. 1990: Use of laser Doppler flowmetry to determine blood flow in and viability of island axial pattern skin flaps in rabbits American Journal of Veterinary Research 51(12): 1914-1921
Hass, W.K.; Ransohoff, J.; Wood, D.H.; Wald, A. 1970: Continuous in vivo monitoring by mass spectrometry of human blood gases and cerebral blood flow Transactions of the American Neurological Association 95: 255-257
Putintsev, M.D. 1988: Mathematical modeling and optimization of plasmadiafiltration Biofizika 33(5): 867-871
Burton, D.J. 2004: Mathematical modeling: a valuable tool Occupational Health and Safety 73(3): 22-24; 26
Kimura, Y.; Nitta, A.; Shimizu, R.; Takayama, H.; Aoki, K. 1988: In vivo measurement of blood flow volume in the monkey retina Nippon Ganka Gakkai Zasshi 92(9): 1489-1496
Kisliakov, I.I. 1976: Dynamics of O2 and CO2 tensions in the brain (mathematical modeling) Biofizika 21(2): 357-361
Dumbadze, G.G.; Antiia, R.V.; Abduladze, T.D.; Chulaia, S.M. 1974: Device for continuous measurement of certain ionometric parameters in the blood flow in vivo Patologicheskaia Fiziologiia i Eksperimental'naia Terapiia 4: 82-83
Luxon, B.A.; Forker, E.L. 1984: Determining hepatic transport kinetics by mathematical modeling Federation Proceedings 43(2): 161-163
Klepper, L.Ia. 1997: Current issues of mathematical modeling and advancement in radiology Voprosy Onkologii 43(5): 538-541
Juricic, D.; Eno, B.E.; Parikh, G. 1974: Mathematical modeling of a virus vector: Culex tarsalis Biomedical Sciences Instrumentation 10: 23-28