A new algorithm for direct volume rendering of medic image series
Wang, X.; Zhao, X.; Gui, Y.; Yang, P.; Lin, T.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 16(3): 324-328
1999
ISSN/ISBN: 1001-5515 PMID: 12552755 Document Number: 504608
In this paper, a new algorithm based on Voxel Model is proposed. This algorithm combines the advantages of surface rendering and direct volume rendering. In the process of 3D reconstruction, OpenGL graphic standard and hardware accelerator can be used. By doing so, better reconstruction, result and fast speed can be achieved. Also, it is simple to turn this algorithm into programs.
Document emailed within 1 workday
Related Documents
Tao, L.; Wang, H.; Tian, Z. 2006: An improved fast algorithm for ray casting volume rendering of medical images Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 23(5): 1003-1007Bignell, C.M.; Dunlop, P.J.; Brophy, J.J.; Jackson, J.F. 1996: Volatile leaf oils of some south-western and southern Australian species of genus Eucalyptus (Series I). Part XIII. (Series I). (a) Series Subulatae, (b) Series Curviptera, (c) Series Contortae, (d) Series Incognitae, (e) Series Terminaliptera, (f) Series Inclusae, (g) Series Microcorythae and (h) Series Cornutae Flavour and Fragrance Journal 11(6): 339-347
Bickton, F.M.; Lillie, T. 2019: Strengthening human resources for health in resource-limited countries: the case of Medic to Medic in Malawi Malawi Medical Journal: the Journal of Medical Association of Malawi 31(1): 99-101
Liu, D.-X.; Wang, C.-L.; Liu, L.; Dong, Z.-Y.; Ke, H.-F.; Yu, Z.-Y. 2006: The accuracy of 3D-CT volume rendering for craniofacial linear measurements Shanghai Kou Qiang Yi Xue 15(5): 517-520
Levoy, M. 1991: Methods for improving the efficiency and versatility of volume rendering Progress in Clinical and Biological Research 363: 473-488
Saba, L.; Pascalis, L.; Mallarini, G. 2009: Multi-detector-row CT of muscles with volume rendering technique Panminerva Medica 51(1): 43-49
Satoh, T. 2001: Delineation of cerebral aneurysms with fly-through imaging of 3D-MRA using perspective volume rendering No Shinkei Geka. Neurological Surgery 29(2): 181-186
Kerr, J.; Ratiu, P.; Sellberg, M. 1996: Volume rendering of visible human data for an anatomical virtual environment Studies in Health Technology and Informatics 29: 352-370
Stredney, D.; Ebert, D.S.; Svakhine, N.; Bryan, J.; Sessanna, D.; Wiet, G.J. 2005: Emphatic, interactive volume rendering to support variance in user expertise Studies in Health Technology and Informatics 111: 526-531
Brassinne, A. 1981: Only direct blood volume determination enables the distinction between polycythemia due to plasma volume reduction and true, primary or secondary polyglobulia Revue Medicale de Liege 36(13-14): 553-555
Gong, J.-c.; Tang, K.-l.; Wang, H.-q.; Li, J.-q.; Chen, W.; Cao, H.-h.; Chen, L. 2009: Measurement of humeral head retroversion angle with multislice spiral computerized tomography volume rendering technique Zhonghua Yi Xue Za Zhi 89(9): 601-605
Huo, X.-k.; Wei, S.; Cheng, Z.-y. 2006: A 3-D image reconstruction algorithm based on helical CT raw data Zhongguo Yi Liao Qi Xie Za Zhi 30(4): 284-286
Cademartiri, F.; Mollet, N.; Nieman, K.; Alfieri, O.; Krestin, G.P. 2004: Images in cardiovascular medicine. Motion-free ECG-gated 16-row multislice computed tomography in the follow-up of aortic coarctation with three-dimensional volume rendering Italian Heart Journal: Official Journal of the Italian Federation of Cardiology 5(2): 167-168
Hou, W.; Mo, Y. 2003: Image reconstruction in electrical impedance tomography based on genetic algorithm Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 20(1): 107-110
Fortmeier, D.; Mastmeyer, A.; Handels, H. 2014: An Image-based Multiproxy Palpation Algorithm for Patient-Specific VR-Simulation Studies in Health Technology and Informatics 196: 107-113
Buckey, J.C.; Beattie, J.M.; Gaffney, F.A.; Nixon, J.V.; Blomqvist, C.G. 1984: Simplified right ventricular volume algorithm using one digitized view and transducer tilt angle Computers in Cardiology 11: 399-402
Tang, C.; Dong, S.; Ning, Y.; Cui, Y. 2012: Tracking of neural stem cells in high density image sequence based on Topological constraint combined with Hungarian algorithm Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 29(4): 597-603
Kovalishin, V.V.; Tetko, I.V.; Luĭk, A.I.; Chretien, J.R.; Livingstone, D.J. 2001: Application of neural networks using the volume learning algorithm for the study of structure-activity relationship in chemical compounds Bioorganicheskaia Khimiia 27(4): 303-313
Rusyn, V.I.; Peresta, I.I.; Chavarha, M.I. 2002: Mathematical algorithm for the determination of admissible volume of surgical intervention for portal hypertension in patients with liver cirrhosis Klinichna Khirurhiia 7: 11-13
Veĭp, I.A.; Vlasova, M.M.; Mazurov, A.I.; Elinson, M.B. 2000: A number of x-rage image intensifiers of the URI-612 series Meditsinskaia Tekhnika 5: 28-31