Chemical reactions of the copper intrauterine device
Oster, G.K.
Fertility and Sterility 23(1): 18-23
1972
ISSN/ISBN: 0015-0282 PMID: 5061813 Document Number: 482804
Document emailed within 1 workday
Related Documents
Munteanu, O.; Cirstoiu, M.; Antoniac, I.; Cirstoiu, C. 2016: Comparison of Pain Level During and After Intrauterine Device Insertion: Levonorgestrel-Releasing Intrauterine System Versus the Copper T Intrauterine Device Environmental Engineering and Management Journal 15(5): 965-972Dallenbach-Hellweg, G.; Dallenbach, F.D.; Sievers, S. 1979: Microscopic, micro-chemical and fluorescent optical findings in endometrium with a copper-T intrauterine device in situ Geburtshilfe und Frauenheilkunde 39(7): 575-579
Brunie, A.él.; Stankevitz, K.; Nwala, A.A.; Nqumayo, M.; Chen, M.; Danna, K.; Afolabi, K.; Rademacher, K.H. 2021: Expanding long-acting contraceptive options: a prospective cohort study of the hormonal intrauterine device, copper intrauterine device, and implants in Nigeria and Zambia LANCET. Global Health 9(10): E1431-E1441
Brunie, A.él.; Stankevitz, K.; Nwala, A.A.; Nqumayo, M.; Chen, M.; Danna, K.; Afolabi, K.; Rademacher, K.H. 2021: Expanding long-acting contraceptive options: a prospective cohort study of the hormonal intrauterine device, copper intrauterine device, and implants in Nigeria and Zambia LANCET. Global Health 9(10): E1431-E1441
Brunie, A.él.; Stankevitz, K.; Nwala, A.A.; Nqumayo, M.; Chen, M.; Danna, K.; Afolabi, K.; Rademacher, K.H. 2021: Expanding long-acting contraceptive options: a prospective cohort study of the hormonal intrauterine device, copper intrauterine device, and implants in Nigeria and Zambia LANCET. Global Health 9(10): E1431-E1441
Xue, H.; Xu, N.; Zhang, C. 1998: Corrosion behavior of copper in a copper bearing intrauterine device in the presence of indomethacin Contraception 57(1): 49-53
Zipper, J.A.; Tatum, H.J.; Medel, M.; Pastene, L.; Rivera, M. 1971: Contraception through the use of intrauterine metals. I. Copper as an adjunct to the "T" device. the endouterine copper "T" American Journal of Obstetrics and Gynecology 109(5): 771-774
Xue, H.; Xu, N.; Zhang, C. 1998: Effect of stainless steel on corrosion behavior of copper in a copper-bearing intrauterine device Advances in Contraception: the Official Journal of the Society for the Advancement of Contraception 14(2): 153-160
Gupta, I.; Kaushalya, S.; Gupta, K.R.; Mahajan, U.; Prasad, R.; Ganguly, N.K. 1994: Copper levels and reactive oxygen species in uterine flushings in copper intrauterine contraceptive device users Indian Journal of Medical Research 100: 225-227
Bilgehan, F.; Dilbaz, B.; Karadag, B.; Deveci, C.D. 2015: Comparison of copper intrauterine device with levonorgestrel-bearing intrauterine system for post-abortion contraception Journal of Obstetrics and Gynaecology Research 41(9): 1426-1432
Bosco-Lévy, P.; Gouverneur, A.; Langlade, C.; Miremont, G.; Pariente, A. 2019: Safety of levonorgestrel 52 mg intrauterine system compared to copper intrauterine device: a population-based cohort study Contraception 99(6): 345-349
Akintomide, H.; James, A.; Moffat, M.; Barnes, P.; Rankin, J. 2022: Systematic review of copper intrauterine contraception continuation in young nulliparous women based on intrauterine device type Bmj Open 12(10): E060606
Akintomide, H.; James, A.; Moffat, M.; Barnes, P.; Rankin, J. 2022: Systematic review of copper intrauterine contraception continuation in young nulliparous women based on intrauterine device type Bmj Open 12(10): E060606
Ng, Y.W.; Liang, S.; Singh, K. 2009: Effects of Mirena (levonorgestrel-releasing intrauterine system) and Ortho Gynae T380 intrauterine copper device on lipid metabolism--a randomized comparative study Contraception 79(1): 24-28
Shen, O.; Ben Chetrit, A.; Margalioth, E.J.; Lavie, O.; Rabinowitz, R.R. 2008: Effects of a copper-medicated intrauterine device on ovarian artery, uterine artery, and intrauterine blood flow Gynecologic and Obstetric Investigation 66(4): 253-256
Imperato, F.; Perniola, G.; Mossa, B.; Marziani, R.; Perniola, F.; Stragapede, B.; Napolitano, C. 2002: The role of copper-releasing intrauterine device or levonorgestrel-releasing intrauterine system on uterine bleeding and iron status (prospective study of 8 years) Minerva Ginecologica 54(3): 271-278
Foreman, H. 1973: Copper seven intrauterine device. Clinical experience Minnesota Medicine 56(6): 474-479
Shaamash, A.H.; Sayed, G.H.; Hussien, M.M.; Shaaban, M.M. 2005: A comparative study of the levonorgestrel-releasing intrauterine system Mirena versus the Copper T380A intrauterine device during lactation: breast-feeding performance, infant growth and infant development Contraception 72(5): 346-351
Shaamash, A.H.; Sayed, G.H.; Hussien, M.M.; Shaaban, M.M. 2005: A comparative study of the levonorgestrel-releasing intrauterine system Mirena® versus the Copper T380A intrauterine device during lactation : breast-feeding performance, infant growth and infant development Contraception (Stoneham) 72(5): 346-351
Netland, P.A.; Netland, A.T.; Solomon, M.B.; Kaiser, J.S. 1983: Ovarian pregnancy with a Copper-7 intrauterine device in situ Journal of Family Practice 16(2): 389-390; 394-395