Isolated tricuspid valve replacement with bioprosthesis
Zaouali, M.; Mahdhaoui, A.; Doghri, A.; Farhati, A.; Drissa, H.
La Tunisie Medicale 74(12): 553-556
1996
ISSN/ISBN: 0041-4131 PMID: 9506058 Document Number: 465283
Document emailed within 1 workday
Related Documents
Jara, F.M.; Magilligan, D.J.; Toledo-Pereyra, L.H.; Davila, J.C. 1979: Management of tricuspid valve insufficiency. Replacement with Hancock bioprosthesis or suture annuloplasty Journal of Cardiovascular Surgery 20(5): 463-466Yao, H.; Miyamoto, T.; Murata, H. 1993: Long-term results of isolated mitral valve replacement using bioprosthesis Nihon Kyobu Geka Gakkai 41(6): 969-974
Villablanca, P.A.; Shah, A.M.; Briceno, D.F.; Zaidi, A.N.; Chau, M.; Garcia, M.J.; Slovut, D.; Taub, C. 2017: Transcatheter Valve-in-Valve Implantation: Failing Tricuspid Bioprosthesis in a Patient with Ebsteins Anomaly Journal of Heart Valve Disease 26(1): 114-117
Staab, M.E.; Nishimura, R.A.; Dearani, J.A. 1999: Isolated tricuspid valve surgery for severe tricuspid regurgitation following prior left heart valve surgery: analysis of outcome in 34 patients Journal of Heart Valve Disease 8(5): 567-574
Sato, T.; Isomura, T.; Suma, H.; Horii, T.; Kobashi, T.; Kanemitsu, H. 2000: Aortic valve/root replacement using a stentless bioprosthesis (Medtronic Freestyle valve) Kyobu Geka. Japanese Journal of Thoracic Surgery 53(4): 301-304
Mori, T.; Kitamura, S.; Verruno, E.; Kenaan, G.; Kay, J.H. 1974: Tricuspid valve replacement. a comparative experimental study with Starr-Edwards ball valve, Beall disc valve, and Kay-Shiley disc valve with muscle guard Journal of Thoracic and Cardiovascular Surgery 68(1): 30-36
Remadi, J.P.; Duveau, D. 2004: Long-term results of mechanical valve replacement: isolated mitral valve replacement and mitral-aortic valve replacement Journal of Heart Valve Disease 13(Suppl 1): S26
Murata, S.; Kobayashi, A. 1989: A successfully operated case of isolated tricuspid insufficiency due to traumatic laceration of anterior leaflet of tricuspid valve Nihon Kyobu Geka Gakkai 37(10): 2217-2222
Hirai, M.; Maki, S.; Yasuda, T.; Kondo, M. 1997: A case report on prosthetic valve dysfunction of the Carpentier-Edwards pericardial bioprosthesis in the tricuspid position associated with remarkable hypoproteinemia Kyobu Geka. Japanese Journal of Thoracic Surgery 50(9): 771-775
Fukui, S.; Matsumiya, G.; Matsue, H.; Sawa, Y. 2007: Stentless bioprosthesis for aortic valve replacement Nihon Geka Gakkai Zasshi 108(2): 73-79
Ostrowski, S.ła.; Zasłonka, J.; Walczak, A.; Stefaniak, B.; Jaszewski, R.; Jander, S.ła.; Iwaszkiewicz, A. 2004: Tricuspid valve surgery secondary to mitral and aortal valve replacement Kardiologia Polska 60(Suppl 1): i
Nakano, K.; Koyanagi, H.; Hashimoto, A.; Ohtsuka, G.; Nojiri, C. 1994: Tricuspid valve replacement with the bileaflet St. Jude Medical valve prosthesis Journal of Thoracic and Cardiovascular Surgery 108(5): 888-892
Ohtsuka, G.; Kitamura, M.; Ishitoya, H.; Tsukui, H.; Hachida, M.; Aomi, S.; Hashimoto, A.; Koyanagi, H. 1997: Simultaneous tricuspid valve operation in patients undergoing aortic and mitral double valve replacement Kyobu Geka. Japanese Journal of Thoracic Surgery 50(5): 351-355; Discussion: 355-357
Keon, W.J. 1983: Role of the porcine bioprosthesis in cardiac valve replacement Canadian Journal of Surgery. Journal Canadien de Chirurgie 26(2): 98
Morita, S.; Yasui, H. 2000: Aortic valve replacement with stentless bioprosthesis: operative methods and pitfalls Kyobu Geka. Japanese Journal of Thoracic Surgery 53(4): 305-309
Zannis, K.; Joffre, J.ér.ém.; Czitrom, D.; Folliguet, T.; Noghin, M.; Lansac, M.N.E.; Mitchell-Heggs, L.; Debauchez, M.; Laborde, F. 2014: Aortic valve replacement with the perceval S bioprosthesis: single-center experience in 143 patients Journal of Heart Valve Disease 23(6): 795-802
Thiene, G.; Bortolotti, U.; Panizzon, G.; Milano, A.; Gallucci, V. 1980: Pathological substrates of thrombus formation after heart valve replacement with the Hancock bioprosthesis Journal of Thoracic and Cardiovascular Surgery 80(3): 414-423
Hatcher, C.R.; Craver, J.M.; Jones, E.L.; Bone, D.K.; Guyton, R.A. 1983: The porcine bioprosthesis. a review of 1,000 consecutive patients undergoing cardiac valve replacement American Surgeon 49(1): 6-10
Wellens, F.; Jacques, G. 1987: Tricuspid valve replacement Cardiovascular Clinics 17(2): 111-115
Murakami, T.; Eishi, K.; Nakano, S.; Kobayashi, J.; Sasako, Y.; Isobe, F.; Kosakai, Y.; Kito, Y.; Kawashima, Y. 1996: Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results Journal of Heart Valve Disease 5(1): 45-49