Ultrasonographic evaluation of uterine perforation by an intrauterine device

Degesys, G.E.; Panella, J.S.; Moyle, J.; Rochester, D.

Journal of Ultrasound in Medicine Official Journal of the American Institute of Ultrasound in Medicine 1(9): 375

1982


ISSN/ISBN: 0278-4297
PMID: 6152961
DOI: 10.7863/jum.1982.1.9.375
Document Number: 426053
A case is reported of a 31-year-old woman who had a copper-7 IUD inserted two years prior to admission but became pregnant and had a normal delivery a year prior to admission. The IUD had not exited her body during delivery, and she was asymptomatic. Ultrasonography was used to locate the IUD, which was extending through the wall of the uterus. Upon mini-laparotomy, the IUD was found to be completely outside of the uterus, embedded in the omentum. This represents the first reported case which documents the use of ultrasonographic technology to locate an IUD extending through a uterine wall.

Document emailed within 0-6 h
Secure & encrypted payments