The repair of inguinal and/or crural hernias with giant Mersilene prostheses in the preperitoneal position
Pricolo, R.; Parziale, A.; Rizzitelli, E.; Lacchini, C.; Cerri, G.; Salvatori, P.
Minerva Chirurgica 48(18): 1007-1010
1993
ISSN/ISBN: 0026-4733 PMID: 8290140 Document Number: 417055
The authors present 44 patients operated for hernias (inguinal and/or femoral) with a median pre-peritoneal approach positioning a mersilene mesh with Stoppa's technique. The results are very interesting considering that the hernias treated are all at high risk of recurrence. We had 4 complications (1 bleeding and 3 wound infections) that were conservatively treated, no mortality at all. The follow-up was of 12 months (mean) and no recurrence was discovered.