Rationale for maximum permissible concentration and methods for determination of trichloroacetaldehyde in atmospheric air
Shipulina, Z.V.; Tepikina, L.A.; Kartashova, A.V.
Gigiena i Sanitariia 10: 6-7
1993
ISSN/ISBN: 0016-9900 PMID: 8163239 Document Number: 406900
Gas-chromatographic method of trichloroacetaldehyde (TCAA) determination in ambient air was developed. Its possibilities for TCAA analysis are within 0.015-0.5 mg/m3. The threshold of its irritating olfactory action was determined. The maximal single-exposure permissible concentration of TCAA is 0.03 mg/m3.