Intraocular pressure after cataract extraction with implantation of an intraocular lens

Jabłoński, J.; Kozak, U.; Bedkowski, Z.

Klinika Oczna 92(9-10): 171-172

1990


ISSN/ISBN: 0023-2157
PMID: 2102952
Document Number: 363216
The subject of our investigations was the behaviour of the IOP after extracapsular and intracapsular operations with implantation of artificial lenses as well into the anterior as into posterior chamber. The investigations were performed on the material of 395 eyes operated in the years 1985-1988. It was established that after these operations glaucoma is a very rare complication.