Rapid headspace gas chromatographic method for assessment of oxidative stability of cooked chicken meat

Ang, C.Y.; Young, L.L.

Journal - Association of Official Analytical Chemists 72(2): 277-281

1989


ISSN/ISBN: 0004-5756
PMID: 2708276
Document Number: 347403
Experiments were conducted to determine the volatile compounds in cooked chicken meat using a static headspace gas chromatographic (GC) technique. Preheating conditions for samples in vials were tested at 70, 80, and 90 degrees C for 20-120 min at each temperature. The majority of the peaks increased in size as the temperature and time increased. Optimum conditions were established as preheating at 80 degrees C for 30 min followed by analysis on a packed column of 8% Poly MPE on Tenax GC with the temperature programmed from 50 to 200 degrees C at 10 degrees/min. Coefficients of variation for major peaks ranged from 8.3 to 14.7%. These results were compared with those obtained with a capillary column analysis of samples preheated at the same conditions. Cooked and stored chicken patties, pretreated with different levels of sodium tripolyphosphate, were analyzed by the thiobarbituric acid (TBA) method and the headspace GC technique. Significant positive correlations were obtained between TBA numbers and the areas of 3 major peaks of the headspace profiles, indicating the applicability of the rapid headspace GC method for the determination of oxidative changes in chicken meat.