Results with the Ionescu-Shiley bioprosthesis
Jendresen, M.; Hjelms, E.
Ugeskrift for Laeger 151(23): 1472-1474
1989
ISSN/ISBN: 0041-5782 PMID: 2734953 Document Number: 342068
During the period 1.1.1982-31.12.1987, 61 patients were submitted to operative introduction of the Ionescu-Shiley pericardial xenograft. The indications were anticipated brief survival or conditions which rendered anticoagulation therapy undesirable. Because of this, the operative lethality was high (12/61). No thromboembolic complications were observed during a period of observation of up to five years and no cases of primary destruction of valvular tissue.
Document emailed within 1 workday
Related Documents
Bachet, J.; Francoual, M.; Landau, J.F.; Brodaty, D.; Dubois, C.; Schlumberger, S.; Goudot, B.; Guilmet, D. 1984: Median-term results of the Ionescu-Shiley valve bioprosthesis (98 patients) Archives des Maladies du Coeur et des Vaisseaux 77(8): 946-952Ochi, M.; Tanaka, S.; Ikeshita, M.; Osaka, S.; Nitta, T.; Terada, K.; Yamauchi, H.; Shoji, T. 1993: Malfunction of mitral and tricuspid Ionescu-Shiley pericardial xenografts Kyobu Geka. Japanese Journal of Thoracic Surgery 46(2): 178-181
Ionescu, M.I.; Tandon, A.P.; Mary, D.A.; Abid, A. 1977: Heart valve replacement with the Ionescu-Shiley pericardial xenograft Journal of Thoracic and Cardiovascular Surgery 73(1): 31-42
Revuelta, J.M.; Duran, D.; Figueroa, A.; Vega, J.L.; Duran, C.M. 1984: The Ionescu-Shiley pericardial bioprostheses in the aortic position. a 5-year perspective Journal of Cardiovascular Surgery 25(3): 199-204
Coelho, A.T.; Ott, D.A.; Cooley, D.A.; Reul, G.J. 1980: Ionescu-Shiley valve: hemodynamic evaluation and clinical follow-up in 325 patients Arquivos Brasileiros de Cardiologia 35(4): 335-339
Walley, V.M.; Keon, W.J. 1987: Patterns of failure in Ionescu-Shiley bovine pericardial bioprosthetic valves Journal of Thoracic and Cardiovascular Surgery 93(6): 925-933
Ionescu, M.I.; Chidambaram, M.; Hasan, S.S.; Tandon, A.P.; Smith, D.R. 1982: Ten years experience with the Ionescu-Shiley pericardial xenograft heart valve Nihon Kyobu Geka Gakkai 30(4): 488-502
Abe, M.; Sakai, A.; Hanayama, N.; Lin, Z.B.; Oosawa, M. 1997: Reoperation for malfunction of Ionescu-Shiley bovine pericardial bioprosthetic valves in the mitral position--special consideration with emergency operation Nihon Kyobu Geka Gakkai 45(1): 17-22
Cohen-Solal, A.; Leroy, G.; Hittinger, L.; Fernandez, F.; Gay, J.; Gourgon, R. 1986: Hemodynamic evaluation of the Carpentier-Edwards porcine bioprosthesis and the Hancock pericardial bioprosthesis in aortic position Archives des Maladies du Coeur et des Vaisseaux 79(3): 346-354
Arpesella, G.; Mikus, P.M.; Cirillo, M.; Bombardini, T.; Pierangeli, A.; Fiume, C.; Vivirito, M.; Piccinino, C.; De Gasperis, C.; Morea, M. 1994: New bileaflet bioprosthesis: early and mid term results Journal of Heart Valve Disease 3(4): 445-450
Lindblom, D. 1988: Long-term clinical results after mitral valve replacement with the Björk-Shiley prosthesis Journal of Thoracic and Cardiovascular Surgery 95(2): 321-333
Yao, H.; Miyamoto, T.; Murata, H. 1993: Long-term results of isolated mitral valve replacement using bioprosthesis Nihon Kyobu Geka Gakkai 41(6): 969-974
Santini, F.; Auriemma, S.; Casali, G.; Rossi, A.; Lusini, M.; Mazzucco, A. 2001: Long-term results with the Xenomedica porcine bioprosthesis in the mitral position Journal of Heart Valve Disease 10(6): 789-794
Murakami, T.; Eishi, K.; Nakano, S.; Kobayashi, J.; Sasako, Y.; Isobe, F.; Kosakai, Y.; Kito, Y.; Kawashima, Y. 1996: Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results Journal of Heart Valve Disease 5(1): 45-49
Meyns, B.; Szecsi, J.; Flameng, W.; Daenen, W. 1994: Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: mid-term clinical results Journal of Heart Valve Disease 3(1): 66-70
Peronace, B.; Cornelli, U.; Marcazzan, E.; Pellegrini, A. 1980: Aortic valve replacement with Starr-Edwards and Björk-Shiley prosthesis. Long term results and statistical analysis of some risk factors Giornale Italiano di Cardiologia 10(8): 1024-1030
Soots, G.; Stankowiak, C.; Warembourg, H.; Pol, A.; Watel, A.; Prat, A.; Devulder, J.P.; Dufay, C.; Moreau, D.; Noblet, D. 1989: Durability of the Carpentier-Edwards porcine bioprosthesis in aortic or mitral positions. 10 years' results on 458 surgically treated cases Annales de Chirurgie 43(8): 616-623
Horstkotte, D.; Loogen, F.; Kleikamp, G.; Schulte, H.D.; Trampisch, H.J.; Bircks, W. 1983: Effect of prosthetic heart valve replacement on the natural course of isolated mitral and aortic as well as multivalvular diseases. Clinical results in 783 patients up to 8 years following implantation of the Björk-Shiley tilting disc prosthesis Zeitschrift für Kardiologie 72(9): 494-503
D'Onofrio, A.; Mazzucco, A.; Valfrè, C.; Zussa, C.; Martinelli, L.; Casabona, R.; Mazzola, A.; Gherli, T.; Badano, L.P.; Fabbri, A. 2011: Left ventricular remodeling, hemodynamics and early clinical outcomes after aortic valve replacement with the Pericarbon Freedom stentless bioprosthesis: results from the Italian Prospective Multicenter Trial Journal of Heart Valve Disease 20(5): 531-539
Solem, J.O.; Kugelberg, J.; Ståhl, E. 1984: Immobilization of Björk-Shiley disc valve Journal of Thoracic and Cardiovascular Surgery 88(4): 640